Fireplace Installation 

  Site Selection and Preparation 

Assemble the mantel 

5. 

surround kit (refer to the 

mantel assembly instructions) 

or construct the custom 

surround with an opening of 

26 ½ inches wide X 23 inches 

high (67.3 cm wide X 58.4 cm 

high) allowing a depth of 12 

This section provides easy step 

by step instructions for installation 

of your fireplace.

Install Trim Kit to front of 

1. 

fireplace by positioning trim 

then pushing straight forward 

against the fireplace.

Make sure the unit is 

2. 

switched off (refer to 

operating instruction section).
Plug the fireplace into a 15 

3. 

Amp/120 Volt outlet.  If the 

cord does not reach you may 

use a extension cord rated for 

a minimum of 1875 Watts.
Push the fireplace into place 

4. 

so that the trim is against the 

finished mantel surround or 

wall surface (Figure 3)
Level, if required with wood 

5. 

shims (not included).

 WARNINg:  

Ensure the 

power cord is not installed so 

that it is pinched or against a 

sharp edge and ensure that 

the power cord is stored or 

secured to avoid tripping or 

snagging to reduce the risk of 

fire, electric shock or injury to 

persons.

 

Wall or

Mantel

Insert

Push

Trim

Figure 3

inches (30.5 cm) (Figure 2B).

 WARNINg:  

Do not attempt 

to wire your own new outlets 

or circuits.  To reduce the risk 

of fire, electric shock or injury 

to persons, always use a 

licensed electrician.

Summary of Contents for DFP6755N

Page 1: ...ORMATION Always read this manual first before attempting to install or use this fireplace For your safety always comply with all warnings and safety instructions contained in this manual to prevent pe...

Page 2: ...and techniques which if not carefully followed will result in damage to the equipment Warning Procedures and techniques which if not carefully followed will expose the user to the risk of fire seriou...

Page 3: ...nty Please record your model and serial numbers below for future reference model and serial numbers can be found on the Model and Serial Number Label of your fireplace NO NEED TO RETURN TO THE STORE Q...

Page 4: ...y unit with a damaged cord or plug or if the heater has malfunctioned or if Important Instructions the fireplace has been dropped or damaged in any manner Return heater to authorized service facility...

Page 5: ...lug one blade is wider than the other The plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified el...

Page 6: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio...

Page 7: ...inches 30 5 cm deep Figure 1 You should allow inch 0 6 cm around the fireplace insert for ease of installation This fireplace does not require any venting CAUTION Clearance for air circulation beneat...

Page 8: ...ce NOTE 1 A 15 Amp 120 Volt circuit is required A dedicated circuit is preferred but not essential in all cases A dedicated circuit will be required if after installation the circuit breaker trips or...

Page 9: ...NG Construction and electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire electrical shock and injury to persons Mantel Surround Ki...

Page 10: ...g the fireplace into a 15 3 Amp 120 Volt outlet If the cord does not reach you may use a extension cord rated for a minimum of 1875 Watts Push the fireplace into place 4 so that the trim is against th...

Page 11: ...ht Control Turn the interior light control knob to increase or decrease the brightness of the interior light D LED Indicators Indicates the current function of the fireplace E 3 Position Switch Pressi...

Page 12: ...without being reset It can be reset by switching the On Off Switch to Off and waiting five 5 minutes before switching the unit back on CAUTION If you need to continuously reset the heater unplug the...

Page 13: ...e ON button located 5 on the remote control Figure 5 This will synchronize the remote control and receiver Remote Control Usage The remote control operates the fireplace levels sequentially flames onl...

Page 14: ...set which generate the flames and embers Helpful Hints It is a good idea to replace all light bulbs at one time if they are close to the end of their rated life Group replacement will reduce the numbe...

Page 15: ...he socket while 4 screwing in the new bulb Replace the log by pushing 5 it down and in until it rests against the partially reflective glass Upper Light Bulb Requirements Quantity of two 2 clear chand...

Page 16: ...bility or fitness for a particular purpose and the entire risk of as to the quality and performance of the products is with the purchaser and in the event of a defect the purchaser assumes the entire...

Page 17: ...by Dimplex or its authorized service representatives or otherwise altered This limited warranty does further not apply to defects resulting from misuse abuse accident neglect incorrect installation i...

Page 18: ...business and all labour costs Such costs shall not be the responsibility of Dimplex For surrounds mantels and trims for the period ending at midnight on the first anniversary of the date of first pur...

Page 19: ...DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO THE PURCHASER How State and Provincial law apply This limited warr...

Page 20: ...tor 3000240200KIT Flicker Rod Assembly 6900190400RP Power Cord 4100040200RP Strain Relief 8500260003RP Flame Speed Control Board 3000240100RP Light Control Board 3000250100RP Partially Reflective Glas...

Reviews: