Dimplex DF2305 Service Manual Download Page 5

5

ExPLODED PARTS DIAgRAM

6

18

2

3

4

5

22

10

13

7

12

15

11

1

16

14

REPLACEMENT PARTS

Log Set Assembly

1. 

 . . . . . . . . . . . . . . . .10438200700RP

Flicker Motor

2. 

 . . . . . . . . . . . . . . . . . . . . .2000220100RP

Heater Assembly (with cutout)

3. 

 . . . . . . .2200490800RP

Thermostat

4. 

 . . . . . . . . . . . . . . . . . . . . . 2300150100RP*

Cutout

5. 

 . . . . . . . . . . . . . . . . . . . . . . . . . .2300270100RP

Heater Switch

6. 

 . . . . . . . . . . . . . . . . . . . .2800070200RP

Capacitor

7. 

 . . . . . . . . . . . . . . . . . . . . . . . .3200030100RP

Terminal Block

8. 

 . . . . . . . . . . . . . . . . . . . .4000070100RP

Power Cord

9. 

 . . . . . . . . . . . . . . . . . . . . . .4100090104RP

Lampholder with leads

10. 

 . . . . . . . . . . . . .4200121000RP

Flicker Rod

11. 

 . . . . . . . . . . . . . . . . . . . . . .5900340100RP

Partially Reflective Glass

12. 

 . . . . . . . . . . .5900350100RP

Front Glass

13. 

 . . . . . . . . . . . . . . . . . . . . . .5900380100RP

Remote Control

14. 

 . . . . . . . . . . . . . . . . . . .3000370500RP

Remote Control Receiver

15. 

 . . . . . . . . . . .3000380200RP

Control Knob

16. 

 . . . . . . . . . . . . . . . . . . . . .8800000300RP

Fireplace Foot (not shown)

17. 

 . . . . . . . . . .8800090100RP

3 Position Switch

18. 

 . . . . . . . . . . . . . . . . . .2800071100RP

DF2305 Trim Parts

Left Side Trim

19. 

 . . . . . . . . . . . . . . . . .1010660159RP

Right Side Trim

20. 

 . . . . . . . . . . . . . . .1010660259RP

Top Trim

21. 

 . . . . . . . . . . . . . . . . . . . . .1010670159RP

Control Cover

22. 

 . . . . . . . . . . . . . . . . .1010620159RP

DF2307SS (Stainless Steel) Trim Parts

19. Left Side Trim  . . . . . . . . . . . . . . . .1010660380RP
20. Right Side Trim . . . . . . . . . . . . . . .1010660480RP
21. Top Trim . . . . . . . . . . . . . . . . . . . . .1010670280RP
22. Control Cover  . . . . . . . . . . . . . . . .1010620280RP

23. DFB2306 Trim Parts

. . . . . . . . . . . . . .  9600440159RP

23. DFS2308 (Stainless Steel) Trim

 . . . . 9600440180RP

DFB4047 

Left/Right/Top Trim . . . . . . . . . . 6900080100RP
22. Control Cover . . . . . . . . . . . .1010620159RP

20

21

19

23

Summary of Contents for DF2305

Page 1: ...mplex North America Limited Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 1 888 346 7539 www dimplex com REV PCN DATE 02 5 DEC 11 IMPORTANT SAFETY INFORMATION Always r...

Page 2: ...chniques which if not carefully followed will expose the user to the risk of fire serious injury or death Operation 3 Maintenance 4 Exploded Parts Diagram 5 Replacement Parts 5 Wiring Diagram 6 Light...

Page 3: ...ailer for recycling advice in your area Operation A 3 Position Switch The power switch has two 2 On positions marked with I and II The I position is for manual operation In this position the built in...

Page 4: ...insert 4 approximately one 1 inch Examine the bulb s to determine which bulb s require 5 replacement Unscrew the bulbs counter clockwise 6 Insert new bulbs 7 Slide the light assembly back into the ins...

Page 5: ...Front Glass 13 5900380100RP Remote Control 14 3000370500RP Remote Control Receiver 15 3000380200RP Control Knob 16 8800000300RP Fireplace Foot not shown 17 8800090100RP 3 Position Switch 18 2800071100...

Page 6: ...6 www dimplex com Wiring Diagram MOD A B Integral Remote MOD 0 No Remote...

Page 7: ...ny maintenance to reduce the risk of electric shock or damage to persons Open the front control cover 1 Figure 6 Figure 7 Remove front glass by removing the 2 outer screws 2 holding the glass clips Fi...

Page 8: ...f to avoid accidental burning of skin WARNING Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons Remove the 4 retaining screws and lift the to...

Page 9: ...and slide into mounting hole Connect all of the wiring connections in their original 10 locations on the terminal block Reassemble in the reverse order as above 11 Capacitor and Terminal Block Replac...

Page 10: ...if cord gets hot to the touch Appearance Fireplace does not turn on Manu ally Improper operation Refer to Operation Section No incoming power from the electrical wall socket Check fuse breaker panel...

Page 11: ...Heater Assembly Heater fan turns on but heater lacks heat Improper operation Refer to Operation Section Loose wiring Trace wiring in unit Defective Thermostat Replace Thermostat Defective Heater Asse...