Dimplex DF2305 Service Manual Download Page 1

Service Manual

23” Compact Fireplace
Model Number:

DF2305

DF2307SS

DFB4047

DFB2306

DFS2308

UL Part Number

6901740000

7400080000R02

In keeping with our policy of continuous product development, we reserve the right to make changes without notice.

© 2011 Dimplex North America Limited

Dimplex North America Limited

1367 Industrial Road   Cambridge ON Canada N1R 7G8

1-888-346-7539   www.dimplex.com

REV PCN

DATE

02

-

5-DEC-11

IMPORTANT SAFETY INFORMATION

: Always read this manual first before attempting to service this 

fireplace. For your safety, always comply with all warnings and safety instructions contained in this 

manual to prevent personal injury or property damage.

DF2305 & 

DF2307SS

DFB4047

DFB2306 & 

DFS2308

Summary of Contents for DF2305

Page 1: ...mplex North America Limited Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 1 888 346 7539 www dimplex com REV PCN DATE 02 5 DEC 11 IMPORTANT SAFETY INFORMATION Always r...

Page 2: ...chniques which if not carefully followed will expose the user to the risk of fire serious injury or death Operation 3 Maintenance 4 Exploded Parts Diagram 5 Replacement Parts 5 Wiring Diagram 6 Light...

Page 3: ...ailer for recycling advice in your area Operation A 3 Position Switch The power switch has two 2 On positions marked with I and II The I position is for manual operation In this position the built in...

Page 4: ...insert 4 approximately one 1 inch Examine the bulb s to determine which bulb s require 5 replacement Unscrew the bulbs counter clockwise 6 Insert new bulbs 7 Slide the light assembly back into the ins...

Page 5: ...Front Glass 13 5900380100RP Remote Control 14 3000370500RP Remote Control Receiver 15 3000380200RP Control Knob 16 8800000300RP Fireplace Foot not shown 17 8800090100RP 3 Position Switch 18 2800071100...

Page 6: ...6 www dimplex com Wiring Diagram MOD A B Integral Remote MOD 0 No Remote...

Page 7: ...ny maintenance to reduce the risk of electric shock or damage to persons Open the front control cover 1 Figure 6 Figure 7 Remove front glass by removing the 2 outer screws 2 holding the glass clips Fi...

Page 8: ...f to avoid accidental burning of skin WARNING Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons Remove the 4 retaining screws and lift the to...

Page 9: ...and slide into mounting hole Connect all of the wiring connections in their original 10 locations on the terminal block Reassemble in the reverse order as above 11 Capacitor and Terminal Block Replac...

Page 10: ...if cord gets hot to the touch Appearance Fireplace does not turn on Manu ally Improper operation Refer to Operation Section No incoming power from the electrical wall socket Check fuse breaker panel...

Page 11: ...Heater Assembly Heater fan turns on but heater lacks heat Improper operation Refer to Operation Section Loose wiring Trace wiring in unit Defective Thermostat Replace Thermostat Defective Heater Asse...