31. Check that the damper mechanism within the heater functions freely,
by rotating the left hand control knob. Check also that the right hand (input)
knob rotates freely.
32. Select the convector heater load appropriate to your recommended
heating design scheme by, if necessary, disconnecting one convector
element by moving either the brown or mauve wire to the empty barrel on
the white terminal block on the internal baf! e.
Model
#CXL12N/CXLS12N
#CXL18N/CXLS18N
CXL24N/CXLS24N
Brown Wire
Still in Circuit
(Upper Element)
450W
450W
650W
Mauve Wire
Still in Circuit
(Lower Element)
450W
1000W
1350W
Both in
Circuit
900W
1450W
2000W
#Note: if the heater is situated underneath a shelf or overhand up to 250mm
high, then the brown wire should remain in circuit.
33. Holding the bottom edge if the front panel towards you, locate the top
edge of the front panel in the groove at the top of the heater and ensure
that the locating pegs on the rear ! anges of the front panel are located in
the receiving holes in each side panel.
34. Push the bottom of the front panel towards the heater, such that the
bottom ! ange locates under the base.
35. Replace the two front panel securing screws removed in operation 15. A small mirror
placed on the " oor under the heater will help location of the threaded holes in the base. These
may be screwed in by hand most of the way, but should then be tightened using an 8mm AF
socket or open ended spanner.