7.2
Display
Description
Setting range
Settings
Time
Sets the current time
00:00:00
Week day
Sets the current week day
Mo
….
Su
Language
Sets the desired language
DE
EN
FR
Domestic hot water
Setpoint
Sets the desired domestic hot water setpoint
25
...45 °C...
60
Hysteresis
Sets the switching hysteresis
2
...3 K...
10
Lower value
Sets the domestic hot water lower value
0
5 K
10
Min. temperature
Sets the minimum domestic hot water temperature, which should also
not be undershot for the duration of a programmed shut-off time.
15
...25 °C...
40
Time programs
HP block
Time
Sets the start and end time for a heat pump block
00:00 -
00:00
Day
Sets the week day / block of days on which the heat pump block should
be activated
Mo - Su (day)
Mo - Fr (block)
Sa - Su (Block)
Mo - Su (block)
Thermal disinfection
Time
Sets the start time for thermal disinfection
00:00:00
Setpoint
Sets the set temperature for thermal disinfection. The heating element
is additionally used for this function
*(to achieve the increased temperatures, observe Chapt. 2.1 on page
3)
60
...65 °C...
(75)*
Day
Sets the day on which thermal disinfection should be activated
Mo - Su (day)
Mo - Fr (block)
Sa - Su (Block)
Mo - Su (block)
Solar
Switch-on diff.
Sets the temperature difference between the collector and cylinder
temperature at which the solar pump should be switched on
6
...8...
10
Switch-off diff.
Sets the temperature difference between the collector and cylinder
temperature at which the solar pump should be switched off
2
...4...
6
Max. tank temperature
Sets the maximum cylinder temperature that is permissible when solar
gain is available
60
...65 °C...
85
Max. collector temperature
Sets the maximum permissible temperature on the collector
125
...130 °C...
135