12
www.dimplex.com
Fireplace Installation
Flush Mounted Installation -
2x8 Framing
CAUTION:
Two people will be
required for various steps of this
procedure.
1.
Prepare a wall with a framed
opening of 73 in. (185.4 cm) wide
x 18 ½ in. (47 cm) high (Figure 7).
!
NOTE:
It is recommended that the
bottom of the unit not be mounted
higher than 40 in.
(102 cm) from the ground to
maintain an optimized viewing
angle of the flame.
WARNING:
Do not attempt to wire
your own new outlets or circuits. To
reduce the risk of fire, electric shock
or injury to persons, always use a
licensed electrician.
WARNING:
Ensure that the circuit
on which the fireplace is to be
installed has the power cut off at
the service panel until installation
is complete.
2. Lift fireplace and insert into
opening. The fireplace's mounting
trim should be flush against the
wall (Figure 7).
3.
Use the supplied bubble level
to level the fireplace within the
framing, adjust as required.
4.
Drive four supplied mounting
screws through the four mounting
holes located on the inside surface
of the fireplace chassis, into wall
studs (Figure 8).
5. Refer to Front Glass Installation
section for final installation
procedures.
Figure 7
2 x 8 Framing
Mounting hole
Mounting hole
Wall
surface
Figure 8