10
www.dimplex.com
Fireplace Installation
For 240V Installations
Use three conductor, non-metallic
sheath cable with ground wire (4
wires total) for the incoming power
supply on fireplace inserts.
CAUTION:
Use the appropriate
wire to meet local and national
electrical codes for rated power
consumption.
•
Connect the L1 wire from the unit
to the L1 wire from the power
supply.
•
Connect the L2 wire from the unit
to the L2 wire from the power
supply.
•
Connect the N wire from the unit
to the neutral wire from the power
supply.
•
Connect the H1 and H2 wires
together, with a wire connector
and leave them disconnected
from everything.
•
Attach the grounding wire to
the cover with the provided
grounding screw. Place wire in-
between screw and lock washer
and tighten (Figure 4).
•
Reposition the electrical cover
brackets over the wires and
connectors and attach to
fireplace chassis using the screw
removed in step 1 and step 3.
Surface Mount Installation
CAUTION:
Two people will be
required for various steps of this
procedure.
WARNING:
Ensure that the circuit
on which the fireplace is to be
installed has the power cut off at
the service panel until installation
is complete.
1. Determine the mounting location
of the unit so that the wall-
mounting bracket can be installed
into 3 wall studs.
!
NOTE:
It is recommended that
the mounting bracket be installed
56 in. (142 cm) off of the ground
to maintain an optimized viewing
angle of the flame.
2. Hold the wall mounting bracket,
with the bubble level on the top,
on the wall so that the bubble on
the level is centered between the
two black lines.
3. Mark the 4 mounting screw
locations, on the wall, ensuring
that the wall bracket stays level.
(Figure 5)
4. In locations where the screws are
being installed only into drywall,
install the supplied wall anchors
before installing the screw (predrill
if required).