13
Tools Required:
Phillips-Head Screwdriver
1. Follow the instructions for
Preparing Firebox for Service
on page 10.
2. Remove the 4 screws that secure the power supply bracket (
Figure 7 / Figure 8
).
3. Trace the wires from the defective power supply and disconnect the power supply connections from the main
control board and relay board (and adaptor board, for XLF8817-XD and XLF10017-XD models), noting their original
locations. Cut restrictive wire ties.
4. Position the new power supply and secure it using the power supply bracket.
5. Connect the new supply in the correct locations on the main control board and relay board.
6. Replace any wire ties that have been cut. Ensure wires are not too close to the mirrored glass.
7. Reassemble the firebox.
Power Supply Replacement
Relay Board
5 Amp Power Supply
Main Control Board
Models XLF5017-XD, XLF6017-XD, and XLF7417-XD Electronics
Figure 7