T
ECHNICAL
R
EFERENCE
M
ANUAL
8.3.6 Set/Get distance range (s
N
v)
Sets the minimum and maximum distances corresponding to the minimum and maximum analog output current levels.
0...20mA
4...20mA
Aout
=
DIST
−
D
min
D
max
−
D
min
∗
20mA
Aout
=
DIST
−
D
min
D
max
−
D
min
∗
16mA
4mA
Aout
Analog current output
DIST
Actual measured distance
D
min
Distance programmed for the minimum output current
D
max
Distance programmed for the maximum output current
Set Command
Get Command
Command
s
N
v+
xxxxxxxx
+
yyyyyyyy
<trm>
s
N
v<trm>
Return successful
g
N
v?<trm>
g
N
v+
xxxxxxxx
+
yyyyyyyy
<trm>
Return Error
g
N
@E
zzz<trm>
g
N
@E
zzz<trm>
Parameters
N
Module number (0..9)
xxxxxxxx
Minimum distance in 1/10 mm corresponding to 0mA / 4mA
yyyyyyyy
Maximum distance in 1/10 mm corresponding to 20mA
zzz
Error code
Configuration parameters need to be saved (See 8.3.8 Save configuration parameters (sNs) on page 28)
Distance Laser Sensor
Page 27/41
Summary of Contents for DLS-C 15