8 Command set
8.1 General
8.1.1 Command termination <trm>
All commands for the DLS-C(H)/FLS-C(H) are ASCII based and terminated
<trm>
with
<cr><lf>
.
8.1.2 Module identification
N
Since the module can be addressed with the ID switch, the ID is represented in the commands by
N
. At the location of the
N
insert the
Module ID.
8.1.3 Parameter separator
The command syntax uses the '
+
' sign as parameter separator. The '
+
' sign can be replaced by the minus '
-
' sign if applicable by the
command.
8.1.4 Set/Get Commands
All configuration commands that are used to set configuration values can also be used to read the currently set value by omitting the
parameter. The command syntax is described as follows:
Set Command
Get Command
Command
s
N
uof+xxxxxxxx<trm>
s
N
uof<trm>
Return successful
g
N
uof?<trm>
g
N
uof+
xxxxxxxx
<trm>
Return Error
g
N
@E
zzz<trm>
g
N
@E
zzz<trm>
Parameters
N
Module ID
xxxxxxxx
Offset in 1/10 mm; + positive / - negative
zzz
Error code
8.1.5 Startup sequence
After power on, the DLS-C(H)/FLS-C(H) does all the initializations and sends a start sequence
g
N
?
. On this sequence, the
N
stands for the
Module ID. After sending this start sequence, the DLS-C(H)/FLS-C(H) is ready to use.
Distance Laser Sensor
Page 20/41