background image

2002 Dimension One Spas Export Owner’s Manual 

 

Glossary of Terms 

 

Term   

Definition 

Bleeder Valve 

 

A small valve used to relieve or expel air from the spa’s plumbing or pump. 

Circulation 

Pump 

 

A pump that circulates the water in the spa continuously. 

Dry Firing 

 

Turning the heater element on when there is no water in the heater. 

Equipment 

Access Panel 

 

Provides access to your spa’s equipment for a qualified service technician.   

Filter Cartridge 

 

Your spa’s filters have been designed so that you may repeatedly clean and 
maintain the filter element as needed.  The element is constructed of woven 
polyester rather than paper to ensure long life and proper filtration. 

GFCI-Ground 

Fault Circuit 

Interrupter 

 

A type of Circuit Breaker that automatically disconnects power to the spa when 
there is an electrical power leakage to ground. 

Gravity Drain 

Valve

 

 

Used to drain your spa 

Halogens 

 

Free chlorine, bromine or iodine ions that are very strong oxidizers used to 
sanitize water. 

ICON Pad 

 

This is a pad accessed by pressing the Dimension One Spas Logo on the far right 
of the Top Side Control Panel. 

Jets 

 

Return the water into the spa from the equipment.  The jets produce a turbulent 
flow of water mixed with air to provide a concentrated body massage 

Light 

 

Illuminates the spa 

Load Sharing 

 

When the circuit breaker size is smaller than the total power needed to operate 
both the heater and the jet pump at the same time, load sharing automatically 
turns off the heater when a jet pump is turned onto high speed. 

Lower Control 

System

 

 

The electronic control system that governs all of the electrically operated 
components of your spa utilizes an advanced microprocessor and solid-state 
electronic devices to activate all user and maintenance options. A backlit, highly 
reliable liquid crystal display gives you a complete update of the spa status at any 
time of the day or night. Temperature setting, as well as control of the light, jets, 
filtration, and time of day display, are all instantly available from, and controllable 
at, the topside control panel. 

Ozone 

Generator 

 

A specialized ultraviolet light that changes oxygen into ozone for use in the water 
sanitation process. 
 
 
 

Flow Switch

   

Safety device(s) that sends a signal to the electronic control system that there is 
adequate water flow to turn the heater on. 

Pump

   

Produces water flow through the heater, filter, sanitation system and the main 
jets in the spa. The pump will operate automatically during filtration and heat 
cycles. This pump can also be operated manually by depressing the “jets” pad on 
the topside control panel which will allow you to choose between two speeds 

• 

Low speed for efficient water circulation during heating and filtration 
modes, and for gentle jet resistance or massage action. 

• 

High speed for maximum jet action.   

Selector Valve 

 

Located on the top edge of the spa, it diverts jet power from one area of the spa 
to another. 

Serial Number 

 

Please use the serial number (located on the left corner pedestal) in 
communication with your dealer. 

Slice Valves / 

Shutoff Valves

 

 

Valves located within the spa’s internal plumbing, which are used by service 
personnel to shut off water flow to the heater and pumps.  All valves must be 

 

30

Summary of Contents for 2002 Arena

Page 1: ...i...

Page 2: ...2002 Dimension One Spas Export Owner s Manual ii...

Page 3: ...HP CALIENTE AND TRIAD 7 Top Side Control 7 Digital Display Messages 9 OH Overheat Protection 9 Flashing LED on the Control Panel 9 Flashing Temperature on the Display 9 Summer Mode 9 Standby Mode 9 Us...

Page 4: ...d the Triad II 18 Control Panel Description 18 Massage Zone Description 20 Operating the Dynamic Massage Sequencer 21 Initial Startup 21 ROUTINE EQUIPMENT MAINTENANCE 24 DRAINING YOUR EQUIPMENT 24 FIL...

Page 5: ...f metal surfaces if each metal surface is permanently connected by a minimum No 8 AWG 8 4 mm2 solid copper conductor attached to the wire connector on the grounding lug inside the equipment compartmen...

Page 6: ...re not covered under warranty Hyperthermia Prolonged immersion in hot water may induce hyperthermia A description of the causes symptoms and effects of hyperthermia are as follows Hyperthermia occurs...

Page 7: ...maintenance of spa water is necessary to maintain safe water and prevent possible damage to spa components Caution Use the spa straps and clip tie downs to secure the cover when not in use This will...

Page 8: ...with a Warning Sign and an Important Notice label This label outlines safety precautions This sign should be permanently placed in a location that is visible to the spa user Replacement signs can be o...

Page 9: ...tile adds a distinctive touch Polyethylene floor completely seals the hot tub eliminating moisture or insect intrusion Built in automatic freeze protection Automatic high low speed filtration cycles...

Page 10: ...be used in conjunction with your Ultra Pure or CrystalZone Water Management Systems The advantage of Vision over conventional halogens bromine and chlorine is that it will as a result of lower chemic...

Page 11: ...is assured through design concepts and materials that meet or exceed CE rating Digital Control Figure 3 lets you relax and enjoy everything your hot tub has to offer Note Gain a thorough knowledge of...

Page 12: ...al hot tub water temperature will again be indicated The hot tub will heat to the pre set temperature automatically 5 5 PROGRAM Pad The PROGRAM pad is used for several different functions including Cl...

Page 13: ...34 F 16 6 C or 134 F 56 6 C DO NOT ENTER THE WATER The system has detected a problem Contact your local Authorized Dimension One Spas Dealer or authorized service center Summer Mode The SUMMER MODE f...

Page 14: ...o a flashing AM or PM indicator Adjust the indicator with the Up and Down Pads When the desired indicator is displayed push the Program Pad to accept the selection and enter the Filter Cycle Start Tim...

Page 15: ...rora XLT Caliente HP Californian Chairman Chairman II Diplomat Nautilus and Triad II Advanced microprocessor technology has been utilized to produce the Scrolling Message Center The most technological...

Page 16: ...GHT Pad 1 Push LIGHT pad once to activate the brightest setting A second push will activate medium setting and a third push will activate the dimmest setting A message indicating current light intensi...

Page 17: ...enheit Pressing the logo for 5 seconds will place the spa in the Standby mode and allow the spa to be cleaned without turning off the power 8 8 Heat Status Light This Light is illuminated whenever the...

Page 18: ...lay we recommend that you have your hot tub inspected by your dealer as a preventative maintenance measure To reset this message push and hold the Dimension One Spas ICON logo pad located at the right...

Page 19: ...MODE feature temporarily disables the circulation pump Cool Off cycle During hot weather the spa can experience Heat Creep Heat creep is caused when the spa during normal maintenance operations canno...

Page 20: ...xit the time setting mode You will then be prompted to set the filter start time Filter Cycle Start Time After setting the time of day the top line of the Digital Display will read SET FILTER CYCLE TI...

Page 21: ...inside and outside the hot tub To invert the text simply push the ENTER pad three times To return the text to its original position repeat this process push the ENTER pad three times Control Panel Loc...

Page 22: ...read RESET PROGRAMMING The bottom line of the Digital Display will read IF SO PUSH ICON 4 Push the Dimension One ICON pad to reset the entire control system to factory defaults or do not touch a pad...

Page 23: ...particular moment during the sequence and wants to keep it for an extended period of time the user may press the Begin Pause pad and the system will remain in the specific configuration until the pad...

Page 24: ...ntrollable and interchangeable with directional jets These jets can be adjusted to change the area of coverage and the speed of the rotational pattern Zone 3 This zone is designed to massage the middl...

Page 25: ...ndicated by an illuminated SEQUENCE Indicator Light 1 through 6 Note If the time between sequence changes is too fast or too slow you can push the SPEED pad to increase or decrease the time between se...

Page 26: ...screw the cap onto the end of the hose bib 6 Check the pump unions Figures 10 and 11 to be sure that they are tight to prevent the possibility of leakage in the equipment compartment 1 Typical Locatio...

Page 27: ...properly Note Ozone bubbles will continue to release from the skimmer recess Ultra Pure bleeder valve as long as the valve remains open Once the pumps are primed be sure that the bleeder is closed tig...

Page 28: ...s Then pulls the basket assembly straight up to remove Next remove the E Z Lock Filter cartridge by twisting the cartridge 1 4 turn counterclockwise to its stop Be careful not to overturn the filter T...

Page 29: ...oughly rinse the shell After cleaning you will want to restore your hot tub shell s original luster by using Dimension One Spas Poli Gloss Caution Do not use 409 type cleaners or other caustic solutio...

Page 30: ...he system has proper electrical power and water level Therefore a fully operational system is your number one defense against freeze damage If you find it completely necessary to drain your water duri...

Page 31: ...h bleeder valves from the top of the filter canister area Place hose of a high pressure air blower into the rear most bleeder fitting first Confirm that water mist is blowing from one or both of the c...

Page 32: ...t the cover from warping or breaking You can even tarp the system at this point for maximum protection Spring Time Startup In the spring or when your ready to start the system back up follow these ins...

Page 33: ...irty or chemically unbalanced water and cleaning of the hot tub filter are also the responsibility of the hot tub owner 5 Hot tub shell or equipment damage caused by improper water maintenance Serious...

Page 34: ...high speed Lower Control System The electronic control system that governs all of the electrically operated components of your spa utilizes an advanced microprocessor and solid state electronic devic...

Page 35: ...erature sensor is used to control the spa heater and the temperature is displayed on the spa side control panel Top Side Control Panel Used to control temperature pumps for jets spa light system clock...

Page 36: ...ptom Problem Corrective Action Will not turn on in any mode No power Check circuit breaker and or GFCI Turns on by itself Normal automatic daily power filtration or anti freeze cycle No action require...

Page 37: ...ve turned 2 Turn the Diverter Valve clockwise or counter clockwise 3 Dirty Filter 3 Clean Filter 4 Air lock 4 Loosen pump union to allow air to bleed No Jet Action or action is poor 5 Gate valve close...

Page 38: ...2002 Dimension One Spas Export Owner s Manual 34...

Page 39: ...2002 Dimension One Spas Export Owner s Manual 35...

Page 40: ...2002 Dimension One Spas Export Owner s Manual 36...

Reviews: