background image

2002 Dimension One Spas Export Owner’s Manual 

 

8.  Remove the filter and fill your hot tub with a hose through the empty filter compartment to a level of one 

to two inches above the bottom of the tile line. 

 
9.  Remove the two shipping bolts located on the front of the pump mount and ensure that the gate valves 

on the pump(s) are in the open position (handles fully extended). 

 

10.  Turn on the circuit breaker (not supplied by Dimension One Spas). Flashing dashed lines will appear for 

30 seconds on the Digital Display followed by the current water temperature (flashing).  

 

11.  Push the JETS 1 and 2 pads to turn both pumps onto high speed. Let the system run for 30 to 45 seconds 

to prime the pumps. If there is no jet action, then the water level is too low or there is air trapped in the 
plumbing lines. To eliminate the trapped air, turn the pumps on and off several times to force the trapped 
air through the pumps. If there is still no jet action, and the bleeder valves have been open for some time, 
turn off the pumps and loosen the top pump unions slightly to let any trapped air escape. Re-tighten the 
pump unions and turn the pumps on again. Turn the pumps on and off several times until jets function 
properly. 

 

 

      Note

 

 
Ozone bubbles will continue to release from the skimmer recess Ultra Pure bleeder valve as long as 
the valve remains open. Once the pumps are primed, be sure that the bleeder is closed tightly. 

 

12.  When the jets are in full operation, close the bleeder valves and push the UP pad until the desired hot tub 

temperature is indicated on the display screen. The screen will then read100

°

 F (38

°

 C) for thirty seconds 

to allow the thermostat time to read the correct current water temperature. Then, the screen will 
display the current hot tub water temperature. 

 

13.  Once you have verified that the heater is functioning, you can reinstall the equipment compartment panel 

removed in Step 1. 

 

 

   Warning 

While setting the temperature, the Digital Display will read out the temperature up to 104

°

 F (40

°

 

C). Water temperatures in excess of 104

°

 F (40

°

 C) should be used with extreme 

caution. 

 

 

 

      Note

 

 
Depending upon the size of the hot tub and the size of the circuit breaker used, heating will occur 
at the rate of 3

°

 F (1.65

°

 C) to10

°

 F (5.5

°

 C) per hour. 

 

14.  After completing the above steps, it is necessary to ensure proper water chemistry. See the Water Care 

Guide accompanying this manual for instructions on maintaining clean and safe water. The schedule shown 
may require more frequent adjustment depending on the bather load. 

15. 

Place the thermal cover on the hot tub to conserve energy and to keep it ready for use

.

 

 

23

Summary of Contents for 2002 Arena

Page 1: ...i...

Page 2: ...2002 Dimension One Spas Export Owner s Manual ii...

Page 3: ...HP CALIENTE AND TRIAD 7 Top Side Control 7 Digital Display Messages 9 OH Overheat Protection 9 Flashing LED on the Control Panel 9 Flashing Temperature on the Display 9 Summer Mode 9 Standby Mode 9 Us...

Page 4: ...d the Triad II 18 Control Panel Description 18 Massage Zone Description 20 Operating the Dynamic Massage Sequencer 21 Initial Startup 21 ROUTINE EQUIPMENT MAINTENANCE 24 DRAINING YOUR EQUIPMENT 24 FIL...

Page 5: ...f metal surfaces if each metal surface is permanently connected by a minimum No 8 AWG 8 4 mm2 solid copper conductor attached to the wire connector on the grounding lug inside the equipment compartmen...

Page 6: ...re not covered under warranty Hyperthermia Prolonged immersion in hot water may induce hyperthermia A description of the causes symptoms and effects of hyperthermia are as follows Hyperthermia occurs...

Page 7: ...maintenance of spa water is necessary to maintain safe water and prevent possible damage to spa components Caution Use the spa straps and clip tie downs to secure the cover when not in use This will...

Page 8: ...with a Warning Sign and an Important Notice label This label outlines safety precautions This sign should be permanently placed in a location that is visible to the spa user Replacement signs can be o...

Page 9: ...tile adds a distinctive touch Polyethylene floor completely seals the hot tub eliminating moisture or insect intrusion Built in automatic freeze protection Automatic high low speed filtration cycles...

Page 10: ...be used in conjunction with your Ultra Pure or CrystalZone Water Management Systems The advantage of Vision over conventional halogens bromine and chlorine is that it will as a result of lower chemic...

Page 11: ...is assured through design concepts and materials that meet or exceed CE rating Digital Control Figure 3 lets you relax and enjoy everything your hot tub has to offer Note Gain a thorough knowledge of...

Page 12: ...al hot tub water temperature will again be indicated The hot tub will heat to the pre set temperature automatically 5 5 PROGRAM Pad The PROGRAM pad is used for several different functions including Cl...

Page 13: ...34 F 16 6 C or 134 F 56 6 C DO NOT ENTER THE WATER The system has detected a problem Contact your local Authorized Dimension One Spas Dealer or authorized service center Summer Mode The SUMMER MODE f...

Page 14: ...o a flashing AM or PM indicator Adjust the indicator with the Up and Down Pads When the desired indicator is displayed push the Program Pad to accept the selection and enter the Filter Cycle Start Tim...

Page 15: ...rora XLT Caliente HP Californian Chairman Chairman II Diplomat Nautilus and Triad II Advanced microprocessor technology has been utilized to produce the Scrolling Message Center The most technological...

Page 16: ...GHT Pad 1 Push LIGHT pad once to activate the brightest setting A second push will activate medium setting and a third push will activate the dimmest setting A message indicating current light intensi...

Page 17: ...enheit Pressing the logo for 5 seconds will place the spa in the Standby mode and allow the spa to be cleaned without turning off the power 8 8 Heat Status Light This Light is illuminated whenever the...

Page 18: ...lay we recommend that you have your hot tub inspected by your dealer as a preventative maintenance measure To reset this message push and hold the Dimension One Spas ICON logo pad located at the right...

Page 19: ...MODE feature temporarily disables the circulation pump Cool Off cycle During hot weather the spa can experience Heat Creep Heat creep is caused when the spa during normal maintenance operations canno...

Page 20: ...xit the time setting mode You will then be prompted to set the filter start time Filter Cycle Start Time After setting the time of day the top line of the Digital Display will read SET FILTER CYCLE TI...

Page 21: ...inside and outside the hot tub To invert the text simply push the ENTER pad three times To return the text to its original position repeat this process push the ENTER pad three times Control Panel Loc...

Page 22: ...read RESET PROGRAMMING The bottom line of the Digital Display will read IF SO PUSH ICON 4 Push the Dimension One ICON pad to reset the entire control system to factory defaults or do not touch a pad...

Page 23: ...particular moment during the sequence and wants to keep it for an extended period of time the user may press the Begin Pause pad and the system will remain in the specific configuration until the pad...

Page 24: ...ntrollable and interchangeable with directional jets These jets can be adjusted to change the area of coverage and the speed of the rotational pattern Zone 3 This zone is designed to massage the middl...

Page 25: ...ndicated by an illuminated SEQUENCE Indicator Light 1 through 6 Note If the time between sequence changes is too fast or too slow you can push the SPEED pad to increase or decrease the time between se...

Page 26: ...screw the cap onto the end of the hose bib 6 Check the pump unions Figures 10 and 11 to be sure that they are tight to prevent the possibility of leakage in the equipment compartment 1 Typical Locatio...

Page 27: ...properly Note Ozone bubbles will continue to release from the skimmer recess Ultra Pure bleeder valve as long as the valve remains open Once the pumps are primed be sure that the bleeder is closed tig...

Page 28: ...s Then pulls the basket assembly straight up to remove Next remove the E Z Lock Filter cartridge by twisting the cartridge 1 4 turn counterclockwise to its stop Be careful not to overturn the filter T...

Page 29: ...oughly rinse the shell After cleaning you will want to restore your hot tub shell s original luster by using Dimension One Spas Poli Gloss Caution Do not use 409 type cleaners or other caustic solutio...

Page 30: ...he system has proper electrical power and water level Therefore a fully operational system is your number one defense against freeze damage If you find it completely necessary to drain your water duri...

Page 31: ...h bleeder valves from the top of the filter canister area Place hose of a high pressure air blower into the rear most bleeder fitting first Confirm that water mist is blowing from one or both of the c...

Page 32: ...t the cover from warping or breaking You can even tarp the system at this point for maximum protection Spring Time Startup In the spring or when your ready to start the system back up follow these ins...

Page 33: ...irty or chemically unbalanced water and cleaning of the hot tub filter are also the responsibility of the hot tub owner 5 Hot tub shell or equipment damage caused by improper water maintenance Serious...

Page 34: ...high speed Lower Control System The electronic control system that governs all of the electrically operated components of your spa utilizes an advanced microprocessor and solid state electronic devic...

Page 35: ...erature sensor is used to control the spa heater and the temperature is displayed on the spa side control panel Top Side Control Panel Used to control temperature pumps for jets spa light system clock...

Page 36: ...ptom Problem Corrective Action Will not turn on in any mode No power Check circuit breaker and or GFCI Turns on by itself Normal automatic daily power filtration or anti freeze cycle No action require...

Page 37: ...ve turned 2 Turn the Diverter Valve clockwise or counter clockwise 3 Dirty Filter 3 Clean Filter 4 Air lock 4 Loosen pump union to allow air to bleed No Jet Action or action is poor 5 Gate valve close...

Page 38: ...2002 Dimension One Spas Export Owner s Manual 34...

Page 39: ...2002 Dimension One Spas Export Owner s Manual 35...

Page 40: ...2002 Dimension One Spas Export Owner s Manual 36...

Reviews: