2002 Dimension One Spas Export Owner’s Manual 

 

Ice 

When “ICE CONDITION” and the water temperature are displayed on the Digital Display, the air temperature in 
the equipment can has gone below a factory-preset level, and the system has activated “Smart Winter Mode.” It 
will then automatically activate the pump(s) to circulate water. This is a normal hot tub function. No corrective 
action is necessary. This feature protects the spa from freezing. 

Cooling 

When “COOLING” and the water temperature are displayed on the Digital Display, the water temperature has 
reached 2

°

 F (1.1

°

 C) above the set temperature. The circulation pump and ozone generator will turn off to allow 

the water to cool back to the set temperature. This is a normal hot tub function. No corrective action is 
necessary. 

 

 

      Note

 

The circulation pump and ozone generator will be on while either jet pump is on and they will remain 
on for 30 minutes after the pump(s) turn off regardless of the water temperature. 

 

 

 

      Note

 

The Dimension One Spas Scrolling Message Center will keep all programming for 40 years with no 
power supply and the time of day for 30 days. This battery back up will not provide power to heat or 
operate the hot tub. 

Summer Mode 

The “SUMMER MODE” feature temporarily disables the circulation pump “Cool Off” cycle. During hot weather 
the spa can experience “Heat Creep”. Heat creep is caused when the spa, during normal maintenance operations, 
cannot dissipate more heat than is generated. This may cause the spa temperature to exceed the set temperature 
and cause a “Cool Off” cycle. In order to prevent the water from becoming cloudy due to the circulation pump 
being turned off by the “Cool Off” cycle, the spa can be set to bypass the “Cool Off” cycle. This is accomplished 
by setting the spa in the “SUMMER MODE”. To initiate a “SUMMER MODE”, use the Up and Down pads to set 
the temperature to 59

°

 F (15

°

 C). The Digital Display will indicate “SUMMER MODE”. In this mode the pump will 

run continuously until the water temperature reaches 107

°

F (41.67

°

 C) and then turns off. It will remain off until 

the water temperature reaches 102

°

 F (38.39

°

 C) at which point the pump turns on. 

Standby Mode 

The “STANDBY” mode allows the user to clean the filter without turning off power to the spa. This feature 
disables all automatic and manual functions. 
 
To enter the “STANDBY” mode press and hold the Dimension One Spa”s ICON logo for 5 seconds. To exit the 
mode, press and hold the logo for 5 seconds. If you do not exit the mode manually, the spa will automatically 
return to normal functionality after 24 hours. 
 

 

      Note

 

 
The “Smart Winter” mode is not affected by the use of the “Standby”: mode. 

 

 

15

Summary of Contents for 2002 Arena

Page 1: ...i...

Page 2: ...2002 Dimension One Spas Export Owner s Manual ii...

Page 3: ...HP CALIENTE AND TRIAD 7 Top Side Control 7 Digital Display Messages 9 OH Overheat Protection 9 Flashing LED on the Control Panel 9 Flashing Temperature on the Display 9 Summer Mode 9 Standby Mode 9 Us...

Page 4: ...d the Triad II 18 Control Panel Description 18 Massage Zone Description 20 Operating the Dynamic Massage Sequencer 21 Initial Startup 21 ROUTINE EQUIPMENT MAINTENANCE 24 DRAINING YOUR EQUIPMENT 24 FIL...

Page 5: ...f metal surfaces if each metal surface is permanently connected by a minimum No 8 AWG 8 4 mm2 solid copper conductor attached to the wire connector on the grounding lug inside the equipment compartmen...

Page 6: ...re not covered under warranty Hyperthermia Prolonged immersion in hot water may induce hyperthermia A description of the causes symptoms and effects of hyperthermia are as follows Hyperthermia occurs...

Page 7: ...maintenance of spa water is necessary to maintain safe water and prevent possible damage to spa components Caution Use the spa straps and clip tie downs to secure the cover when not in use This will...

Page 8: ...with a Warning Sign and an Important Notice label This label outlines safety precautions This sign should be permanently placed in a location that is visible to the spa user Replacement signs can be o...

Page 9: ...tile adds a distinctive touch Polyethylene floor completely seals the hot tub eliminating moisture or insect intrusion Built in automatic freeze protection Automatic high low speed filtration cycles...

Page 10: ...be used in conjunction with your Ultra Pure or CrystalZone Water Management Systems The advantage of Vision over conventional halogens bromine and chlorine is that it will as a result of lower chemic...

Page 11: ...is assured through design concepts and materials that meet or exceed CE rating Digital Control Figure 3 lets you relax and enjoy everything your hot tub has to offer Note Gain a thorough knowledge of...

Page 12: ...al hot tub water temperature will again be indicated The hot tub will heat to the pre set temperature automatically 5 5 PROGRAM Pad The PROGRAM pad is used for several different functions including Cl...

Page 13: ...34 F 16 6 C or 134 F 56 6 C DO NOT ENTER THE WATER The system has detected a problem Contact your local Authorized Dimension One Spas Dealer or authorized service center Summer Mode The SUMMER MODE f...

Page 14: ...o a flashing AM or PM indicator Adjust the indicator with the Up and Down Pads When the desired indicator is displayed push the Program Pad to accept the selection and enter the Filter Cycle Start Tim...

Page 15: ...rora XLT Caliente HP Californian Chairman Chairman II Diplomat Nautilus and Triad II Advanced microprocessor technology has been utilized to produce the Scrolling Message Center The most technological...

Page 16: ...GHT Pad 1 Push LIGHT pad once to activate the brightest setting A second push will activate medium setting and a third push will activate the dimmest setting A message indicating current light intensi...

Page 17: ...enheit Pressing the logo for 5 seconds will place the spa in the Standby mode and allow the spa to be cleaned without turning off the power 8 8 Heat Status Light This Light is illuminated whenever the...

Page 18: ...lay we recommend that you have your hot tub inspected by your dealer as a preventative maintenance measure To reset this message push and hold the Dimension One Spas ICON logo pad located at the right...

Page 19: ...MODE feature temporarily disables the circulation pump Cool Off cycle During hot weather the spa can experience Heat Creep Heat creep is caused when the spa during normal maintenance operations canno...

Page 20: ...xit the time setting mode You will then be prompted to set the filter start time Filter Cycle Start Time After setting the time of day the top line of the Digital Display will read SET FILTER CYCLE TI...

Page 21: ...inside and outside the hot tub To invert the text simply push the ENTER pad three times To return the text to its original position repeat this process push the ENTER pad three times Control Panel Loc...

Page 22: ...read RESET PROGRAMMING The bottom line of the Digital Display will read IF SO PUSH ICON 4 Push the Dimension One ICON pad to reset the entire control system to factory defaults or do not touch a pad...

Page 23: ...particular moment during the sequence and wants to keep it for an extended period of time the user may press the Begin Pause pad and the system will remain in the specific configuration until the pad...

Page 24: ...ntrollable and interchangeable with directional jets These jets can be adjusted to change the area of coverage and the speed of the rotational pattern Zone 3 This zone is designed to massage the middl...

Page 25: ...ndicated by an illuminated SEQUENCE Indicator Light 1 through 6 Note If the time between sequence changes is too fast or too slow you can push the SPEED pad to increase or decrease the time between se...

Page 26: ...screw the cap onto the end of the hose bib 6 Check the pump unions Figures 10 and 11 to be sure that they are tight to prevent the possibility of leakage in the equipment compartment 1 Typical Locatio...

Page 27: ...properly Note Ozone bubbles will continue to release from the skimmer recess Ultra Pure bleeder valve as long as the valve remains open Once the pumps are primed be sure that the bleeder is closed tig...

Page 28: ...s Then pulls the basket assembly straight up to remove Next remove the E Z Lock Filter cartridge by twisting the cartridge 1 4 turn counterclockwise to its stop Be careful not to overturn the filter T...

Page 29: ...oughly rinse the shell After cleaning you will want to restore your hot tub shell s original luster by using Dimension One Spas Poli Gloss Caution Do not use 409 type cleaners or other caustic solutio...

Page 30: ...he system has proper electrical power and water level Therefore a fully operational system is your number one defense against freeze damage If you find it completely necessary to drain your water duri...

Page 31: ...h bleeder valves from the top of the filter canister area Place hose of a high pressure air blower into the rear most bleeder fitting first Confirm that water mist is blowing from one or both of the c...

Page 32: ...t the cover from warping or breaking You can even tarp the system at this point for maximum protection Spring Time Startup In the spring or when your ready to start the system back up follow these ins...

Page 33: ...irty or chemically unbalanced water and cleaning of the hot tub filter are also the responsibility of the hot tub owner 5 Hot tub shell or equipment damage caused by improper water maintenance Serious...

Page 34: ...high speed Lower Control System The electronic control system that governs all of the electrically operated components of your spa utilizes an advanced microprocessor and solid state electronic devic...

Page 35: ...erature sensor is used to control the spa heater and the temperature is displayed on the spa side control panel Top Side Control Panel Used to control temperature pumps for jets spa light system clock...

Page 36: ...ptom Problem Corrective Action Will not turn on in any mode No power Check circuit breaker and or GFCI Turns on by itself Normal automatic daily power filtration or anti freeze cycle No action require...

Page 37: ...ve turned 2 Turn the Diverter Valve clockwise or counter clockwise 3 Dirty Filter 3 Clean Filter 4 Air lock 4 Loosen pump union to allow air to bleed No Jet Action or action is poor 5 Gate valve close...

Page 38: ...2002 Dimension One Spas Export Owner s Manual 34...

Page 39: ...2002 Dimension One Spas Export Owner s Manual 35...

Page 40: ...2002 Dimension One Spas Export Owner s Manual 36...

Reviews: