Advanced Force Gauge User’s Manual
31
PLC Cable
Supply voltage: The relay is powered from a 5 volt regulator inside the AFG Input
control: The relay state is controlled via a TTL signal from the AFG and is in a
“closed position” when a logic ‘1’ input is applied.
Output characteristics
Peak relay ac voltage:
350 volts
Continuous relay load current or peak ac voltage:
120 mA
Maximum relay peak load current:
300 mA
Typical relay contact resistance at 100 mA:
17 ohms
Isolation voltage between AFG and relay output:
1500 volts AC
Summary of Contents for Quantrol AFG 10
Page 1: ...Advanced Force Gauge AFG AFTI User s Manual ...
Page 4: ...Advanced Force Gauge User s Manual 4 ...
Page 34: ...Advanced Force Gauge User s Manual 34 Stand ...
Page 35: ...Advanced Force Gauge User s Manual 35 Freeze Drop Average Time Rate ...
Page 36: ...Advanced Force Gauge User s Manual 36 Footswitch1 Footswitch2 Comms Constant ...
Page 37: ...Advanced Force Gauge User s Manual 37 Information Calibration Contrast ...
Page 38: ...Advanced Force Gauge User s Manual 38 ...