22
VERSION
version - Under
version
are the Weigh-Tronix part number for
the FI-90 force indicator, and the revision number for
the software found in your unit. Weigh-Tronix part
numbers are divided into two parts: a five-digit prefix
and a four-digit dash number.
dISPLAY
display - From this display:
dISPLAY
, press
PRINT / SE-
LECT
and the top row of annunciators turns on.
Press
PRINT / SELECT
again and a dynamic test is
run. Press
MENU
to stop the dynamic test or
consecutively press
MENU
to step through the
display test routine. Press
PRINT / SELECT
when
the dynamic test is active to return the display to
dISPLAY
.
buttonS
buttons - With
bUttOnS
displayed, press
PRINT / SELECT
and an underscore will appear on the screen. Press
any key except
MENU
to check for proper key
functioning. After testing the keys, press
MENU
to
return the display to
bUttonS
.
OutPutS
outputs - These tests allow you to turn the cutoffs on and off
automatically in sequence, under
CYCLE
, or indi-
vidually, under
CUTOFF 1
and
CUTOFF 2
. When
you exit the outputs test, the cutoffs revert to their
proper condition according to the applied gross force.
input
input
- This test tells you how the remote control input is
configured. It may be off, or it may be configured as
a remote PRINT key control, a remote GROSS /
PEAK key control, or a remote ZERO / CLEAR key
control. With
input
displayed, press
PRINT /
SELECT
and an underscore will appear. Activate the
external remote switch, and the display will print the
name of the key to which the remote input is dedi-
cated, verifying proper functioning of the connection.
VoltAgE
voltage - The input power voltage is displayed in tenths of a
volt. In the battery versions, the BATTERY annuncia-
tor comes on when the voltage reaches approxi-
mately 5.4 volts.
A to d
A to D - Displays the analog-to-digital counts. The span is
normally 20,000 counts per millivolt per volt. With a
calibrator at zero millivolts per volt, the displayed
value should be between -200 and +200.
SEriAL
serial - Tells you if the serial output is ready or busy. A
jumper connecting pins 4 and 8 of the serial port will
cause
READY
to be displayed.
Main Displays Viewed
in the Test Mode Menu
Summary of Contents for FI-90
Page 1: ...Dillon FI 90 Force Indicator User s Manual ...
Page 23: ...23 ...