43
10.
Batch Processing Settings
When multiple settings are required to read the device, setting one by one may be cumbersome.
The user can save all the information that needs to be set as a QR code, and the device can
complete multiple settings after reading the QR code.
The following are the guidelines for batch processing:
1.
Batch processing setting code content format:
@WSM+
[
Command parameter 1
]
,
[
Command parameter 2
]
,
[
Command parameter n
]
For the command parameters that can be set in batches, please refer to Appendix G Batch Setting
Command Parameter List.
2.
Every two parameters are separated by an English semicolon ";", and the end is ended by an
English semicolon. Note that there can be no spaces between the semicolon and the
command.
3.
The batch setting allows up to 30 parameter settings at the same time.
4.
Make the setting content that conforms to the batch processing setting code format as a QR
code in the coding software and read the setting code for batch setting.
For example: turn on the setting code (command parameter: 00000000), induction mode
(command parameter: 02000003), the fill light is on when taking pictures (command parameter:
03000000), single reading time -3000ms (command parameter: 0202001E), prohibition Read the
command code of Interleaved 2 of 5 (command parameter: 070A0100), then the batch setting code
content is as follows:
@WSM00000000; 02000003; 03000000; 0202001E; 070A0100;
When batch setting is required, the setting can be completed by reading the batch setting code that
has been produced.
Note:
1.
When performing batch settings, you must ensure that "setup code is turned on"
2.
If the content of the batch setting code does not meet the setting code rules, or the setting
command parameters are not included in the list of settable parameters, the setting failure
will occur.