background image

D

IGITAL  

C

ONTROL  

I

NCORPORATED 

 

DigiTrak

 FBC 

Operator’s Manual 

3

 

Battery Charger Status Indicators 

The battery charger has red, orange, and green LEDs that are on, off, or flashing depending 
on the charging status. A series of beeps will also sound to indicate a major battery pack or 
charger fault. The following table describes the charger or battery status indicated by the 
various LEDs and audible signals. 

LEDs and  
Audible Signals 

Charger or Battery 
Pack Status 

Status Description 

Action 

Flashing 

Orange

 

No Battery Pack 
Detected 

No battery pack or unknown 
battery type detected. 

Insert viable battery pack. 

Solid 

Green

 & Solid 

Orange

 

Slow Charge / Voltage 
Restoration 

Battery pack voltage is less 
than 11.0 V, or  
Battery pack temperature is 
above 104° F. 

None. Charger will slowly 
restore battery pack to full 
voltage. 

Flashing 

Green

 & 

Solid 

Orange

 

Minor Charger Fault 

Fault detected within charger 
temperature sensor circuitry. 

Charger is safe to use 
temporarily with charge current 
limited to less than 1.0 A, but it 
should be sent in for repair as 
soon as convenient. 

Solid 

Orange

 & 

Solid 

Red

 

Fast Charge 

Normal operation; charge 
duration is approximately  
4 hours. 

None. 

Alternately Flashing 

Green

 & 

Orange

 

Full Charge 

Battery pack is charged to 
100% capacity. 

Remove fully charged battery 
pack. 

Alternately Flashing 

Green

 & 

Red

 

Charge Terminated 

Over-discharged battery pack 
could not be revived within a 
reasonable amount of time, or 
battery pack is in an over-
charged condition. 

Battery pack is damaged or 
near the end of its useable life. 
If battery pack is fairly new and 
in good physical condition, 
contact DCI Customer Service. 
Otherwise, battery pack is 
unrecoverable and should be 
properly recycled. 

Alternately Flashing 

Orange

 & 

Red

 with 

Series of Beeps 

Battery Pack 
Temperature Fault 

Battery pack temperature is 
above 122° F, or battery pack 
temperature is below 32° F. 

If battery pack is hot, try to 
cool it down; if cold, try to 
warm it up. Then recharge 
battery pack. 

Flashing 

Red

 with 

Series of Beeps 

Permanent Battery 
Pack Fault 

Battery pack voltage is less 
than 5.0 V. 

Battery pack is unrecoverable 
and should be properly 
recycled. 

Flashing 

Green

Orange

 & 

Red

 with 

Series of Beeps 

Major Charger Fault 

Unrecoverable hardware 
failure of charger electronics 
detected.  

Stop using charger and send it 
in for repair immediately; 
please contact DCI Customer 
Service. 

Summary of Contents for F Series

Page 1: ...DIGITAL CONTROL INCORPORATED dci digital control com www DigiTrak com FBC F Series Battery Charger Operator s Manual ...

Page 2: ...hing herein shall constitute a warranty by DCI nor will anything herein be deemed to modify the terms of DCI s existing Limited Warranty applicable to all DCI products DCI may update or correct the information in this manual from time to time You may find the most recent version of this manual on DCI s website www DigiTrak com Under Service Support click Documentation and select from the Manuals d...

Page 3: ... 21 6432 5186 86 21 6432 5187 fax dci china digital control com Europe Brueckenstraße 2 97828 Marktheidenfeld Germany 49 9391 810 6100 49 9391 810 6109 fax dci europe digital control com India DTJ 1023 10th Floor DLF Tower A DA District Center Jasola New Delhi 110044 91 11 4507 0444 91 11 4507 0440 fax dci india digital control com Russia Molodogvardeyskaya Street 4 Building 1 Office 5 Moscow Russ...

Page 4: ...Battery Pack 2 Battery Charger Status Indicators 3 Warnings and Precautions 4 Temperature 4 Power Input 4 User Serviceability 4 Liquids 4 Indoor Use 5 System Specifications 5 Power Requirements 5 Environmental Requirements 5 Storage and Shipping Requirements 6 Temperature 6 Packaging 6 Equipment and Battery Disposal 6 LIMITED WARRANTY ...

Page 5: ...d F Series FBP will power an F5 receiver for approximately 10 hours or an FSD remote for approximately 14 hours before recharging is necessary A battery pack can be recharged about 400 times before the battery life is substantially reduced To check the charge status of a battery pack at any time press the battery status button below the five LEDs The LEDs indicate the charge level with each repres...

Page 6: ... If using AC power connect the AC power cord to the AC adapter then plug the adapter into an AC power receptacle If using DC power plug the DC power cord directly into the DC power source Once powered the LEDs on the battery charger will begin to flash in succession and the charger will emit a series of beeps Charging a Battery Pack With the charger connected to a power source and the orange LED f...

Page 7: ...ge Solid Red Fast Charge Normal operation charge duration is approximately 4 hours None Alternately Flashing Green Orange Full Charge Battery pack is charged to 100 capacity Remove fully charged battery pack Alternately Flashing Green Red Charge Terminated Over discharged battery pack could not be revived within a reasonable amount of time or battery pack is in an over charged condition Battery pa...

Page 8: ...us goods and can only be shipped by trained professionals Temperature The temperature of the air around the battery charger should be between 32 to 95 F Charging the battery outside this range may increase charge time harm battery performance or reduce battery life It is important to maintain free airflow around the charger especially near the top and bottom vents If the battery s internal tempera...

Page 9: ...s The power requirements environmental requirements and equipment maintenance requirements for the FBC F Series Battery Charger are listed below Power Requirements Device Model Number Operational Voltage Operational Current DigiTrak F Series Battery Charger FBC Input 10 28 V Output 19 2 V 5 0 A max 1 8 A max Environmental Requirements Device Relative Humidity Operating Temperature DigiTrak F Serie...

Page 10: ... symbol on equipment indicates that the equipment must not be disposed of with your other household waste Instead it is your responsibility to dispose of such equipment at a designated collection point for the recycling of batteries or electrical and electronic equipment If the equipment contains a banned substance the label will show the pollutant Cd Cadmium Hg Mercury Pb Lead near this symbol Be...

Page 11: ... first receipt of the DCI product and immediately notifies DCI of any apparent defect and iii User complies with all of the Warranty Claim Procedures described below 4 The service period for this equipment is five years from the date of manufacture During this period DCI will support the repair or replacement of the products featured in this manual A fee for repairs and replacements may be charged...

Page 12: ...g actual field operations Please have all related equipment available together with a list of all DCI product serial numbers It is important that field troubleshooting be conducted because many problems do not result from a defective DCI product but instead are due to either operational errors or adverse conditions occurring in the User s drilling environment 3 If a DCI product problem is confirme...

Reviews: