The information contained here are property of DIGITAX Automotive Electronics Italy, and extremely confidential. Any disclosure, copying, distribution to third party
is strictly prohibited.
41
VAT
302
The fare-cost is VAT included?
- Should the fare-cost be considered inclusive VAT? If so, on the ticket the fare-cost will be split into cost and VAT.
If not, the fare-cost is considered Exclusive VAT. At the end of the fare the VAT will be added to the fare-cost.
The allowed answer is either: 0 (No: excl. VAT so add) or: 1 (Yes: incl. VAT so split).
0=A 1=S
PRINTER
303
Print ticket if from Stopped to ForHire?
- Should the ticket be printed automatically if from Stopped is being passed to ForHire?
The allowed answer is either: 0 (No: don't print autom.) or: 1 (Yes: print autom.).
No / Yes
304
Print all income for each used tariff?
- Should all income for each used tariff be printed on the ticket?
The allowed answer is either:
0 (No: don't print all income) or: 1 (Yes: print all income).
No / Yes
305
Print all kilometres made for each used tariff?
- Should all kilometres made for each used tariff be printed on the ticket?
The allowed answer is either:
0 (No: don't print all kilometres made) or: 1 (Yes: print all kilometres made).
No / Yes
306
Print the maximum speed of the trip?
- Should the maximum speed of the trip be printed on the ticket?
The allowed answer is either:
0 (No: don't print maximum speed) or: 1 (Yes: print maximum speed).
No / Yes
307
NOT USED for F2 Plus
No / Yes
308
Hide the driver number on the ticket?
- Should the driver number be hidden on the ticket? The allowed answer is either: 0 (No: don't hide) or: 1 (Yes: hide).
No / Yes
309
NOT USED for F2 Plus
No / Yes
IR SENSOR FOR PASSENGER DETECTION
310
Distance to enable registration or ForHire:
this is the distance that enables either the registration of the black fare with a passenger aboard in Stopped or the automatic
activation of Hired. See Q.313. The distance is given in metres with an accuracy of 0.1 meter. The allowed value goes from 0.0 (min) to 6553.5 (max). The digit indicating
multiples of 0.1 m (so at the right of the decimal point) will flash.
0 - 65535
311
IR-sensor for passenger-det. is present?
- Is the Infra-Red-sensor for the detection of passengers present?
The allowed answer is either:
0 (No: not present) or: 1 (Yes: present).
No / Yes
312
IR-sensor contact is normally closed?
- Is the Infra-Red-sensor contact a Normally Closed contact ? If not, then it is a Normally Open contact.
The allowed answer is either:
0 (No: normally open) or: 1 (Yes: normally closed).
0=open
1=closed
313
Black fare registr. or autom. in Hired?
- After the distance programmed in Q.310 should be activated either: the registration in memory of the black fare with a
passenger aboard in Stopped or the automatic activation of Hired? The allowed answer is either: 0 (No: registration) or: 1 (Yes: pass to Hired).
0 = registration
1 = pass to Hired
314
NOT USED for F2 Plus
No / Yes
315
The ForHire led flashes if IR-sensor is ON? -
When the IR-sensor is activated should the ForHire led flash?
The allowed answer is either:
0 (No: don't flash) or: 1 (Yes: flash).
No / Yes
from Q 316 / Available for any possible software extension / to Q 318
STATISTICAL MEMORY BLOCK N.1
319
Inhibit visualization memory-block n. 1?
- Should it be impossible to visualize memory-block number 1? See also Q.320.
The allowed answer is either:
0 (No: visualize) or: 1 (Yes: inhibit).
No / Yes
320
Enable visualization MB1 with password?
- If the visualization of memory-block number 1 has been inhibited (see Q.319) should it be possible to undo this with the
password? The allowed answer is either: 0 (No: keep inhibited) or: 1 (Yes: enable with password).
No / Yes
321
Inhibit printing memory-block n. 1?
- Should it be impossible to print memory-block number 1? See also Q.322.
The allowed answer is either:
0 (No: print) or: 1 (Yes: inhibit).
No / Yes
322
Enable printing MB1 with password?
- If the printing of memory-block number 1 has been inhibited (see Q.321) should it be possible to undo this with the password?
The allowed answer is either:
0 (No: keep inhibited) or: 1 (Yes: enable with password).
No / Yes
323
Inhibit reset of memory-block n. 1?
- Should it be impossible to reset memory-block number 1 from panel? See also Q.324.
The allowed answer is either:
0 (No: reset from panel) or: 1 (Yes: inhibit).
No / Yes
324
Enable reset of MB1 with password?
- If the reset from panel of memory-block number 1 has been inhibited (see Q.323) should it be possible to undo this with the
password? The allowed answer is either: 0 (No: keep inhibited) or: 1 (Yes: enable with password).
No / Yes
325
Inhibit access to stat. Memory n. 1?
- Should it be impossible to have access to the reading-procedure of the statistics-memory number 1?
The allowed answer is either:
0 (No: access) or: 1 (Yes: no access).
No / Yes
ACCESS TO TARIFF PROGRAMMING
326
Programming only with the memory-key?
- Should programming only be possible with the memory-key? If not, then programming is also possible step by step. The
allowed answer is either: 0 (No: also step by step) or: 1 (Yes: only memory-key).
No / Yes
STATISTICAL MEMORY BLOCK N. 2
327
Inhibit visualization memory-block n. 2?
- Should it be impossible to visualize memory-block number 2? See also Q.328.
The allowed answer is either:
0 (No: visualize) or: 1 (Yes: inhibit).
No / Yes