background image

D-FORCE600VA SLIDING GATE OPERATOR

Remote control operating

distance

30m (Frequency:433.92mHz)

Remote control mode

Single button

Output shaft height

48.5mm

Max. gate weight

600Kg

Output torque

14N·m

Limit switch

Magnetic limit switch

Noise

≤56dB

Duty cycle

S2, 15 minutes

extra remote control

20

Environmental temperature

-20°C~+50°C

Gate Move speed

12m/min

14m/min

4.

 

Mechanical Installation 

The D-FORCE600VA will handle gate weighting up to 600kg and up to

8m/12m if the proper installation procedures have been followed.

The D-FORCE600VA gate operator operates by forcing a drive rack by a

drive gear.  The entire configuration is shown in the diagram below. The

gate operator must be installed on the inside of the gate.

                                           

4

Summary of Contents for D-FORCE600VA

Page 1: ...Sliding Gate Operator User s Manual D FORCE600VA...

Page 2: ...elect Auto close function Manual key release designed for emergency purposes 2 Important safety information Carefully read and follow all safety precautions and warning before attempting to install an...

Page 3: ...person can access them by reaching through the gate In the event of power failure an emergency release key allows you to operate the gate manually The operator should be switched off before repairing...

Page 4: ...5 minutes extra remote control 20 Environmental temperature 20 C 50 C Gate Move speed 12m min 14m min 4 Mechanical Installation The D FORCE600VA will handle gate weighting up to 600kg and up to 8m 12m...

Page 5: ...into the concrete when it is poured Wires within the conduit shall be located or protected so that no damage can result from contact with any rough or sharp part Concrete pad The base unit of the gat...

Page 6: ...ee Fig 3 After the concrete has hardened mount the gate operator base to the concrete pad Verify that the base is properly leveled Using bolts and washers mount the gate operator to the base and inser...

Page 7: ...e gate Move the gate manually checking if the rack is resting on the gear and weld the second and third nut Bring another rack element near to the previous one Move the gate manually and weld the thre...

Page 8: ...y and push the sliding gate manually to pre determine the position fix the block to the rack and lock the gear by push up the release bar Moving the gate electrically adjust the block to the proper po...

Page 9: ...to the rack and lock the gear by push up the release bar Moving the gate electrically adjust the block to the proper position until the position of the opening and closing meet the requirement Spring...

Page 10: ...ease key as follow Fit the supplied key in the lock Turn the key and pull down the release bar about 90 to release the gear Note Do not exceed 90 be careful not to use too much force otherwise the rel...

Page 11: ...ATE OPERATOR Fig 7 6 Wire Connecting Make sure that the power is OFF before making any electrical connections Remove the cover perform the wiring See Fig 8 and wiring notes for control board and repla...

Page 12: ...U3 U2 VDR1 Q3 J2 HALL U1 J5 X1 J4 POWER MOTOR Cautionlight ProtectEarth Capacitor Extralbutton switch O S C switch Pedestrianswitch Infared sensor Loopdetector Limit swtich 12VDC GND COM COM COM Learn...

Page 13: ...12 24V AC DC TX Emitter connecting power supply 7 9 8 Control board Terminal J5 Fig 9 infrared Schematic diagram d Three button switch single button switch keypad The D FORCE600VA is equipped with in...

Page 14: ...6 1 2 3 terminal J2 4 5 6 1 2 3 Fig 10A e Pedestrian switch Connect pedestrian switch wire to 4 and 6 terminal of J2 press the switch the door will open 1 meter when the door is closed terminal J2 Swi...

Page 15: ...nect wire see the Fig 11A terminal J2 LOOP 10 11 Control board terminal block Loop detector 12 7 8 9 detector output Fig 11A The car through the loop the door will close itself when the door opened Th...

Page 16: ...output force adjustment to keep safe usage Clockwise rotation to increase counter clockwise rotation to reduce Warning Motor force can not be set too large just drive the door is ok Remote control Th...

Page 17: ...out 2 seconds and then turn off again The learning process is finished Up to 25 remote controls may be used Erase remote controls To erase all existing remote controls press and hold learn button S1 t...

Page 18: ...D FORCE600VA SLIDING GATE OPERATOR Adjust the DIP switch see Fig13B and table 1 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Fig 13A Fig 13B 18...

Page 19: ...3 4 1 2 3 4 1 2 3 4 1 2 3 4 Fig 13C Fig 13D Table 1 DIP switch adjust DIP DIP switch Function SET 1 ON see Fig 13A No soft start mode OFF see Fig 13A Soft start mode need to power on reset 2 ON see Fi...

Page 20: ...sfully otherwise repeat the above setup instruction until your device responds to your expected function 2 If the gate can not be moved please check whether the gate is obstructed or the gate is too w...

Page 21: ...closed position when the limit switch is reached the gate will not move if you press CLOSE button The device is installed with a thermal protector the thermal protector will switch off the motor auto...

Page 22: ...tion see the Fig 8 10 Maintenance Check the door once a month The door should be carefully checked for balance The door must be in good working order We suggest for safety reasons photocells be used o...

Page 23: ...low 2 Transmitter code is lost 1 Replace the battery inside the transmitter 2 Reprogram the transmitter The transmitter operating distance is too short Battery level may be low Replace battery 11 Pack...

Page 24: ...D FORCE600VA SLIDING GATE OPERATOR 2 Transmitter 2 3 Release key 2 4 User s manual 1 24...

Reviews: