background image

D-FORCE1400VA SLIDING GATE OPERATOR

damage can result from contact with any rough or sharp part.

Concrete 

 

 p  ad  

The base unit of the gate operator requires a concrete pad in order to 

maintain proper stability.  The concrete pad should be approximately 

450mm x 300mm x 200mm deep in order to providing for adequate weight 

and structure to insure proper stable installation.

Anchors

 

  (see Fig.2)

You can use anchor bolts, anchors, washers and nuts. These anchors must 

be set into the concrete when it is poured or you can use wedge anchors to 

fasten the operator.

Gate operator

Gear

Groundsill

Input power

Plain washer

Nut

Spring washer

Nut

Fig.2

Ope

 

 rator

 

    b  ase (see Fig.3)

After   the   concrete   has   hardened,   mount   the  gate   operator  base  to   the

concrete pad. Verify that the base is properly leveled.
Using bolts and washers mount the gate operator to the base and insert the

cover. Check the operator and make sure it is lined up with the gate.

                                           

5

Summary of Contents for D-FORCE1400VA

Page 1: ...Sliding Gate Operator User s Manual D FORCE1400VA...

Page 2: ...operator The gate operator should be installed by a qualified technician otherwise serious personal injury or property damage may occur When opening or closing the gate do not attempt to walk or drive...

Page 3: ...uitable for the power supply in your area 3 Main technical parameters Type D FORCE1400VA D FORCE1400VAU Power supply 220V 50Hz 110V 60Hz Motor speed 52rpm 62rpm Rated output power of motor 500W Remote...

Page 4: ...low The gate operator must be installed on the inside of the gate Wall Switch Gate operator Input power Rack Sliding gate Fig 1 Gate preparation Be sure the gate is properly installed and slides smoot...

Page 5: ...ation Anchors see Fig 2 You can use anchor bolts anchors washers and nuts These anchors must be set into the concrete when it is poured or you can use wedge anchors to fasten the operator Gate operato...

Page 6: ...on the gate Move the gate manually checking if the rack is resting on the gear and weld the second and third nut Bring another rack element near to the previous one Move the gate manually and weld the...

Page 7: ...ontally Install the limit block as shown in Fig 5 and Fig 6 The spring limit switch and blocks are used to control the position of the gate Release the gear with the key and push the sliding gate manu...

Page 8: ...g 4 and Fig 5 The magnetic of limit switch and blocks are used to control the position of the gate Release the gear with the key and push the sliding gate manually to pre determine the position fix th...

Page 9: ...OR Gear Sliding gate Rack Limit block Magnetic Magnetic limit Fig 5 M6X10 Spring limit Magnetic limit Fig 6 Manual operation In case of power failure use release key unlock the lock clockwise is unloc...

Page 10: ...manually Note If the gate bumps the mounting post and cannot be electric opened move the gate a few inches by hand thus you can release the gate with the key open and close the gate manually Fig 7 6 W...

Page 11: ...U3 U2 VDR1 Q3 J2 HALL U1 J5 X1 J4 POWER MOTOR Cautionlight ProtectEarth Capacitor Extralbutton switch O S C switch Pedestrianswitch Infared sensor Loopdetector Limit swtich 12VDC GND COM COM COM Learn...

Page 12: ...r 12 24V AC DC TX Emitter connecting power supply 7 9 8 Control board Terminal J5 Fig 9 infrared Schematic diagram d Three button switch single button switch keypad The D FORCE1400VA is equipped with...

Page 13: ...6 1 2 3 terminal J2 4 5 6 1 2 3 Fig 10A e Pedestrian switch Connect pedestrian switch wire to 4 and 6 terminal of J2 press the switch the door will open 1 meter when the door is closed terminal J2 Swi...

Page 14: ...nnect wire see the Fig 11A terminal J2 LOOP 10 11 Control board terminal block Loop detector 12 7 8 9 detector output Fig 11A The car through the loop the door will close itself when the door opened T...

Page 15: ...tput force adjustment to keep safe usage Clockwise rotation to increase counter clockwise rotation to reduce Warning Motor force can not be set too large just drive the door is ok Remote control The r...

Page 16: ...bout 2 seconds and then turn off again The learning process is finished Up to 25 remote controls may be used Erase remote controls To erase all existing remote controls press and hold learn button S1...

Page 17: ...D FORCE1400VA SLIDING GATE OPERATOR 8 Programming Process Adjust the DIP switch see Fig13B and table 1 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Fig 13A Fig 13B 17...

Page 18: ...IDING GATE OPERATOR 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Fig 13C Fig 13D Table 1 DIP switch adjust DIP DIP switch Function SET 1 ON see Fig 13A No soft start mode OFF see Fig 13A Soft start mode need to po...

Page 19: ...tion is not allowed during setting If your device responds to your requested function correctly you have set the function successfully otherwise repeat the above setup instruction until your device re...

Page 20: ...ly stop the gate in the opened and closed positions If the gate stops at opened position when the limit switch is reached the gate will not move if you press OPEN button If the gate stops at closed po...

Page 21: ...e switch is connected the LED will light k LED 12 indicate the Open limit switch status if the switch is connected the LED will light All these LED position see the Fig 8 10 Maintenance Check the door...

Page 22: ...s obstructed 2 Infrared sensor function is enabling but the sensor has not been installed 1 Remove obstructions 2 Make sure the infrared sensor function is disabling Remote transmitter does not work 1...

Page 23: ...an unpack inspection in which you should check whether the product was damaged If you have any problem please contact our dealer You should find the following items in our standard packing N o Item Q...

Reviews: