12
Installation -
Cabling
2
I/O Cable Connection
- not supported. Please use
the terminal block for alarm and sensor connections.
3
Power
Please check the correct rated power.
4
Sensor/alarm input (DI)
Cable of the sensor/alarm input device should
connect to + and - of the Terminal Block.
Alarm out / relay out (DO)
It connects to the alarm lights, siren or lamps
and the sensor types are normal open and
normal close.
5
Audio in
Connect the ‘Audio In’ port of the camera
to the microphone directly or ‘Line Out’
port of the amplifier connected with
microphone.
If the microphone is connected directly, the
microphone with the embedded amplifier
such as condenser mic. needs to be used.
Audio Out
Connect the ‘Audio Out’ port of the camera to
the ‘Line In’ port of the speaker.
If the speaker without the amplifier is
connected to Audio Out port, it doesn’t work
properly. Therefore, the speaker with the
amplifier or the separate amplifier is needed.
Power rate
Power
consumption
PoE
DC 12V
9.3W
IEEE 802.3af Class3
3
4
5
+
-
+
-
+
-
IN COM OUT
DC12V
DI
DO
AUDIO
1
2
3
4 5