7
Installation -
Disassemble the camera
4. Install the moisture packet in the base of the
camera’s lens.
a. Remove the moisture absorber from the
packaging.
b. Cut the card and folder along the dotted
line.
c. Place the moisture absorber around the
camera lens module.
5. Remove the protective film between the dome
and the camera module.
6. Remove the Poron ring before placing the dome
back on the camera. When attaching the dome
back, align the line on the dome with the one on
the base of the camera.
When placing the cover back on the camera, also
make sure to align the cover and bottom case to
match the case outline.
Reset to the Factory Default
Press the reset button for 5 seconds to return the
setup to the factory default.
Warning:
If you press the ‘Reset’ button, you will lose all
setting data. If needed, please, make a note for
further installation.
Poron Ring
Reset Button
Before installing your camera, you have to read the following cautions.
1. The mounting surface must withstand five times the camera weight.
2. Do not let the cables get caught in improper places or the electric line cover can be damaged. This may
cause a short or fire.
3. For the installation process, remove the dome cover from the camera module by loosening the three
(3) screws on the dome. Use the Allen wrench provided with the camera.