XTLplus Series Installation and Programming Guide | Digital Monitoring Products
56
SPECIFICATIONS
Power Supply: Model 372-500-W Plug-In DC Power Supply
Input
120 VAC, 60 Hz
Output
12 VDC
Standby Battery
DMP 3.8 VDC Lithium, 800 mAh
Optional Standby Battery
DMP 3.8 VDC Lithium, 3500 mAh
All circuits inherent power limited
Enclosure
Size
5.50 W x 3.75 H x 1.00 D inches
13.97 W x 9.53 H x 2.54 D cm
Color
White
Communication
Optional 265LTE Series Cellular Communicator to send messages to DMP Model SCS-1R or SCS-VR Central Station
Receivers.
Built-in Wi-Fi network or hardwired Ethernet alarm signal communication to DMP Model SCS-1R or SCS-VR Central
Station Receivers.
Keypads
You can associate up to seven 9000 Series Thinline Keypads or 9862 Series Graphic Touchscreen Keypads, or one
7463 Network Keypad.
Number of Zones
XTLplus Series has 99 wireless initiating zones numbered 1-99.
Zone and Output numbers 51 to 54 and 61 to 64 can support 1144 Series Key Fobs, Output Modules, or sirens.
CERTIFICATIONS
FCC Wireless Receiver and Z-Wave Approvals
FCC ID:
CCKPC0181
IC:
5251A-PC0181
FCC Wi-Fi Network Approvals
FCC ID:
VW4-ATWINC1500
IC:
20266-WINC1500PB
Intertek (ETL) Listed
ANSI/UL 1023
Household Burglar
ANSI/UL 1610
Central Station Burglar
ANSI/UL 985
Household Fire
California State Marshall (CSFM)