Disarmed Output
This output or Z-Wave Favorite turns on when all areas of the panel are disarmed. The
output turns off when an area is armed.
Burglary Output
This output or Z-Wave Favorite turns on any time a burglary zone goes into alarm.
The output turns off when the area in which the alarm occurred disarms and no other
burglary zones are in alarm. Enter 0 (zero) to disable this output.
Arm-Alarm Output
Enter the output or Z-Wave Favorite to turn on steady when any area of the system
is armed. If an alarm occurs causing the keypads to turn Red, this output pulses and
continues to pulse for approximately three (3) minutes after the panel is disarmed.
Enter 0 (zero) to disable.
Wireless Outputs
The Arm-Alarm Output is compatible with the Model 1117 Wireless LED Annunciator
and the Model 1116 Wireless Relay Output connected to a Model 572 Indicator LED.
When the Model 1117 is battery operated, the LED is off when the system is armed to
conserve battery life. If an alarm occurs, the output flashes quickly.
When using the Model 1116 connected to a Model 572, the LED is on when the system
is armed. If an alarm occurs, the output pulses.
To operate the Arm-Alarm output within one second, program a fast response
number from 61 to 64. Fast response operation reduces overall wireless output
battery life.
To operate the Arm-Alarm output within 15 seconds, program a slow response
number from 51 to 54. Slow response operation increases overall wireless output
battery life.
Heat Saver Temperature
Enter the desired temperature setting for all Z-Wave thermostats when the system
is armed ALL or AWAY. When the system is disarmed the thermostats return to their
previous settings. The range is 55-95 degrees. Enter 0 (zero) to disable.
Cool Saver Temperature
Enter the desired temperature setting for all Z-Wave thermostats when the system
is armed ALL or AWAY. When the system is disarmed the thermostats return to their
previous settings. The range is 55-95 degrees. Enter 0 (zero) to disable.
Carbon Monoxide Alarm Output
This output turns on any time a Carbon Monoxide Zone (CO) is placed in alarm. The
output is turned off using Sensor Reset option while no additional CO type zones are
in alarm.
Zone Monitor Output
This output turns on momentarily when a zone monitor tone is activated on keypads.
If zone monitoring is turned off, the zone monitor output will not trigger.
DISARMED OUT: 0
BURGLARY OUT: 0
ARM-ALARM OUT: 0
HEAT SAVER
TEMPERATURE: 0
COOL SAVER
TEMPERATURE: 0
OUTPUT OPTIONS
CO ALRM OUT: XXX
OUTPUT OPTIONS
ZN MNTR OUT: XXX