12
XR500/XR100 Canadian User’s Guide
Introduction
Status List
The keypad Status List displays any alarm or trouble condition on
a zone, and any trouble condition on an internal system monitor.
The system monitors include the AC power, battery power, panel
box tamper, printer, and phone lines. If more than one alarm or
trouble condition occurs at the same time, the keypad sequences
this information on its display.
If the alarm is from a 24-hour zone or a system monitor, it remains
in the Sta tus List until it re stores. If one or more armed burglary
zones trip at the same time, the last one to trip remains in the
Status List. This is to ensure that if a burglary has occurred the
last zone tripped remains displayed even if it has been restored.
Armed Status
Armed Status is the keypad display of the current armed condition
of areas within your security system.
If your system is set up as an Area system with areas one to eight,
the display shows: 1 2 3 4 5 6 7 8. When you arm areas 1, 3, 5, and
7 the keypad displays: 1 3 5 7.
If your Area system is setup with nine or higher areas and the system
is armed, the display reads: ALL SYSTEM ON or SYSTEM ON. Refer to
Checking Armed Areas for information about checking the armed areas.
If your system is set up as a Home/Sleep/Away or All/Perimeter
system, one of the following displays indicate the current Armed
Status:
The keypad displays
When
HOME SYSTEM ON
The perimeter is armed in a Home/
Sleep/Away system.
PERIMETER ON
The perimeter is armed in an All/
Perimeter system.
ALL SYSTEM ON
All areas are armed.
SLEEP SYSTEM ON
The perimeter and interior are armed
but the bedroom area is disarmed.
If your system is set up as a Home/Sleep/Away with Guest system,
the arming status of the main system is the same as a standard
Home/Sleep/Away system. The current arming status of the Guest
systems displays as follows:
The keypad displays
When
HOME GUEST 1 ON
The first guest house perimeter is armed
in a Home/Sleep/Away with Guest
system.
SLEEP GUEST 1 ON
The first guest house perimeter and
interior are armed but the bedroom
area is disarmed.
ALL GUEST 1 ON
All first guest house areas are armed.
Note:
The XR100 system allows one guest house system while the
XR500 allows two guest house systems.
Also, for keypads that include an Armed LED, the Armed LED is
ON steady anytime any area is armed and OFF when ALL areas are
disarmed.
View Zone Status
To view disarmed zones that are in fault, press any Select key when
the status list displays.