![Digital ID View 1611Z-960H Series User'S Installation And Operation Manual Download Page 35](http://html1.mh-extra.com/html/digital-id-view/1611z-960h-series/1611z-960h-series_users-installation-and-operation-manual_2499057035.webp)
CompuLan Center dba/Digital IDView Technologies
12000 Ford Road, Suite 110
, Dallas TX 75234
31
Picture 4.1 Record Configuration
【
Channel
】
Choose the corresponding channel number to set the channel. Choose the all option to
set the entire channels.
【
Redundancy
】
Choose the redundancy function option to implement the file double backup function.
Double backup is writing the video files in two hard disks. When you do the double backup, make
sure that there are two hard disks installed. One is read-write disk and the other is redundant disk.
(refer to 4.5.1)
【
Length
】
Set the time length of each video file. 60minutes is default value.
【
Pre-Record
】
Record 1-30 seconds before the action. (time length is decided by the code stream)
【
Record mode
】
Set video state: schedule, manual or stop.
Schedule:
Record according to the set video type (common, detection and alarm) and time
section.
Manual:
Click the button and the according channel is recording no matter the channel in
any state.
Stop:
Click the stop button and the according channel stops recording no matter the
channel in any state.
【
Period
】
Set the time section of common recording, The recording will start only in the set range.
【
Record type
】
Set recording type: regular, detection or alarm.
Regular:
Perform the regular recording in the set time section. The video file type is “R”.
Detect:
Trigger the “motion detect”, “camera mask” or “video loss” signal. When above
alarm is set as opening recording, the “detection recording” state is on. The video
file type is “M”.
Alarm:
Trigger the external alarm signal in the set time section. When above alarm is set
as opening recording, the “detection recording” state is on. The video file type is “A”.
Note: Refer to chapter 4.3 to set corresponding alarm function.