1.4 Record System Parameters
Save a printout of the system parameters, which you’ll want
to restore after the power conversion and installation of the
KA65A modules.
Example 1–2:
Show All System Parameters
>>> SHOW ALL
1
Type
Rev
! Lists all system parameters,
1+
KA64A
(8082)
0006
! beginning with the system
2+
KA64A
(8082)
0006
! configuration
9+
MS62A
(4001)
0002
A+
MS62A
(4001)
0002
D+
DWMBA/A
(2001)
0002
E+
DWMBA/A
(2001)
0002
XBI D
1+
DWMBA/B
(2017)
0007
4+
KDB50
(010E)
0F1C
6+
DEBNI
(0118)
0100
XBI E
1+
DWMBA/A
(2017)
0007
4+
CIBCA
(0108)
41C1
6+
TBK70
(410B)
0307
Current Primary: 1
! Shows the status of CPUs
/NOENABLED-
/NOVECTOR_ENABLED-
/NOPRIMARY- 2
! Shows the memory interleave
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
NODE #
.
.
.
.
A2
A1
.
.
.
.
.
.
.
.
ILV
.
.
.
.
32
32
.
.
.
.
.
.
.
.
64 Mb
/INTERLEAVE:DEFAULT
/SCOPE
/SPEED: 1200 /BREAK
! Shows the terminal characteristics
English
! Shows the language mode
XMI:D
08-00-2B-08-3D-64
! Shows the Ethernet address
DEFAULT /XMI:E
/BI:4
DU0
! Shows Boot specs saved
DIAG
/R5:00000010
XMI:E
/BI:5 DU1
HSC
/R5:40000000
XMI:D
/BI:2
/NODE:00000405 DU0
>>>
2
! Print the console display for reference.
1–8