3-8
Diagnostics
3.3 Running Diagnostics on DUP-Based Devices
To run diagnostics on a DUP-based device, enter the set host com-
mand to invoke the DUP server on the selected node. You can test
devices associated with the KDM70 (SI) adapter or the KFMSA
(DSSI) adapter.
3.3.1 Testing an SI Device
Example 3-4 is a sample test session of an SI device. The device
tested is a disk associated with the KDM70 adapter.
Example 3-4
Testing an SI Device
P00>>> show device
1
polling for units on kdm700, slot 11, xmi0...
duc1.0.0.11.2 DUC1 RA70
duc2.0.0.11.2 DUC2 RA70
duc3.0.0.11.2 DUC3 RA70
duc213.0.0.11.2 DUC213 RA82
P00>>> set host -dup duc1.0.0.11.2
2
dup: starting DIRECT on kdm70_c.0.0.11.2 ()
DIRECT 1 D Directory Utility
ILEXER 1 D InLine Exerciser
Task? ilexer
3
dup: starting ILEXER on kdm70_c.0.0.11.2 ()