Touch Panel Commands
4-6
FP-770T User's Manual
Conditions and restrictions : Connecting a PS/2 mouse
The following conditions and restrictions apply when a PS/2 type mouse is
used with the FP770T. Due to the effect of the combination of the type of PC,
mouse and OS used, the FP-770T's touch panel may not operate correctly.
(1) If the mouse used with the FP-770T is fully compliant with all PS/2 mouse
standards there should be no usage problems, however, all commercially
available PS/2 mouse products may not be fully compliant. This unit was
developed using the Microsoft Mouse
®.
Microsoft's other mouse products,
the "Itellimouse" and the "3 Button" mouse may not be used with this
unit.
(2) Please be sure that the mouse driver used is the "Microsoft PS/2 Port
Mouse". In the Windows 95/NT "Control Panel" settings area, double-
click on the Mouse icon to bring up the Mouse settings. First, click on the
"Motion" tab, then drag the "Pointer Speed" setting bar to the far left for
the fastest movement. Next, be sure the "Pointer Trail" "Show Pointer
Trail" checkbox is not checked.
(3) The "double-click" feature should be used only for maintenance or when
developing applications, due to mouse operability problems that may occur.
(4) The following PC's may have some coordinate positioning errors.
• When the FP-770T is connected to a PC running the Windows NT OS, if
the video controller used is the TRIO64 ViRGE S3, the touch position
may be slightly skewed.
This phenomenon has been confirmed on the IBM-PC350 and the Fujitsu
FMV-620T6C7 personal computers.
• When using a laptop-type PC, or PC that utilizes both mouse and non-
mouse pointing devices, or a PC that accepts "Hot Plug-in" type devices,
the touch position may be slightly skewed.
This phenomenon has been confirmed on the Toshiba Dynabook 440CDT,
and the SONY VAIO laptop PCs.
(5) This unit is not compatible with OS/2 PCs and devices.
Since OS/2 PCs and devices use the function is not compatible, it cannot
use in this unit.
When using the FP-770T in your system, be sure to test the unit carefully with
all the connected devices.