![Digital Equipment DEChub ONE Installation Manual Download Page 17](http://html1.mh-extra.com/html/digital-equipment/dechub-one/dechub-one_installation-manual_2498910017.webp)
DEChub ONE
13
Product Specifications
Table 2 lists the DEChub ONE physical, environmental, and certification
specifications.
Table 2:
Operating Specifications
Parameter
DEChub ONE
With Attached Module
Physical
Height
44.45 cm (17.5 in)
44.45 cm (17.5 in)
Width
4.45 cm (1.75 in)
4.45 cm (1.75 in)
Depth
10.16 cm (4.0 in)
25.40 cm (10.0 in)
Weight
1.59 kg (3.5 lb)
3.4 kg (7.5 lb)
Connectors
MJ–8, DB-9, 15-pin AUI
MJ–8, DB-9, 15-pin AUI, plus
module connectors
Operating
Environment
Operating
Temperature
5
°
C to 50
°
C
(41
°
F
to 122
°
F)
5
°
C to 50
°
C
(41
°
F
to 122
°
F)
Relative Humidity 10% to 95% noncondensing
10% to 95% noncondensing
Altitude
1
Sea level to 4900 m
(16,000 ft)
Sea level to 4900 m
(16,000 ft)
Input Power
100 Vac to 120 Vac @ 2 A
220 Vac to 240 Vac @ 1 A
N/A
N/A
Output Power
90 watts maximum
50W @+5Vdc,
1W @ +12.0Vdc
30W @ +15.0 Vdc
81 watts available to power
the module.
7 watts available to support
the AUI port.
Maximum power consumption
(DEChub ONE cooling fans,
module, and AUI ) 90 watts.
Certification
CE, CSA, FCC,TÜV, UL, VCCI
CE, CSA, FCC,TÜV, UL, VCCI
1
For high-altitude sites, decrease the operating temperature specification by 1.8
°
C (35.2
°
F)
for each 1000 m (3200 ft).