background image

AlphaServer 8400

Alpha Servers    3.213

Step 6—Storage Controllers (continued)

PCI-based Storage Controllers

KZPAC-AA

PCI one-port SCSI RAID Controller with 4 MB cache memory—Uses one PCI slot. Provides one
fast/wide single-ended connection. Allows RAID levels 0, 1 and 5. Includes RAID Array 230/plus
subsystem software and documentation kit. KFE70-AA EISA Bridge option required. Tape and
optical drives not supported. Maximum of 4 per PCI, maximum of 4 per system supported with
DIGITAL UNIX V3.2G or V4.0B; OpenVMS V6.2-1H3 or v7.1.

KZPAC-CA

PCI three-port SCSI RAID Controller with 4MB cache memory—Uses two PCI slots. Provides
three fast wide/single-ended connections. Allows RAID levels 0, 1 and 5. Includes RAID/Array
230/plus subsystem software and documentation kit. KFE70-AA EISA Bridge option required. Tape
and optical drives not supported. Maximum of four per PCI, maximum of four per system if third port
not used (otherwise maximum of three per PCI, three per system) supported with DIGITAL UNIX
V3.2G or V4.0B; OpenVMS V6.2-1H3 or V7.1. Order BN31K-0E or KZPAC-SB for third port
connection.

KZPAC-CB

PCI three-port SCSI RAID Controller with 8MB cache memory—Uses two PCI slots. Provides
three fast wide/single-ended connections. Allows RAID levels 0, 1 and 5. Includes RAID/Array
230/plus subsystem software and documentation kit. KFE70-AA EISA Bridge option required. Tape
and optical drives not supported. Maximum of four per PCI, maximum of four per system if third port
not used (otherwise maximum of three per PCI, three per system) supported with DIGITAL UNIX
V3.2G or V4.0B; OpenVMS V6.2-1H3 or V7.1. Order BN31K-0E or KZPAC-SB for third port
connection.

BN31S-1E

1.5 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB
system cabinet (in front and rear locations) and BA661-AA. One required for each used port on
KZPSC-BA or KZPAC-CA/CB module.

BN31K-0E

Required for KZPSC-BA or KZPAC-CA/CB to use third port on module. Connects internally from
KZPSC-BA module to second PCI slot/bulkhead.

KZPAC-SB

SCSI cable/bulkhead assembly kit with two ports for KZPSC-BA or KZPAC-CA/CB, allows
connection of two third-port outputs using one PCI bulkhead slot.

BN31S-02

2.0 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB
system cabinet and BA661-AA.

KZPSC-UB

Battery back-up for cache memory option for KZPAC or KZPSC controller.

MS100-BB

8 MB cache memory option; upgrades KZPAC-CA to KZPAC-CB, field installable only.

KZPSC-AA

PCI one-port SCSI RAID Controller—OpenVMS and DIGITAL UNIX support four per PCI,
maximum four per system (uses one PCI slot). KFE70-AA EISA Bridge option required. Provides one
fast/wide/single-ended connection. Allows RAID levels 0, 1, and 5. Tape drives are not supported.

KZPSC-BA

PCI SCSI RAID Controller with three ports—OpenVMS and DIGITAL UNIX support four per
PCI, maximum four per system (uses two PCI slots).  KFE70-AA EISA Bridge option required.
Provides three Fast Wide/single-ended connections. Allows RAID levels 0,1, and 5. Tape drives not
supported. Order BN31K-0E or KZPAC-SB for third port connection.

BN31S-1E

1.5 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB
system cabinet (in front and rear locations) and BA661-AA. One required for each used port on
KZPSC-BA or KZPAC-CA/CB module.

BN31K-0E

Required for KZPSC-BA or KZPAC-CA/CB to use third port on module.  Connects internally from
KZPSC-BA or KZPAC-CA/CB module to second PCI slot/bulkhead.

KZPAC-SB

SCSI cable/bulkhead assembly kit with two ports for KZPSC-BA or KZPAC-CA/CB, allows
connection of two third-port outputs using one PCI bulkhead slot.

BN31S-02

2.0 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB
system cabinet and BA661-AA.

KZPSC-UB

Battery back-up for cache memory option for KZPAC or KZPSC controller.

MS100-AA

16 MB Cache memory option for KZPSC-AA/BA, maximum one per controller, field installable only.

MS100-AB

32 MB Cache memory option for KZPSC-AA/BA, maximum one per controller, field installable only.

KFPSA-AA

PCI DSSI Adapter (OpenVMS only)—Requires OpenVMS V6.2-1H2 or later; minimum
System Console Firmware Revision 3.09. Maximum twelve per PCI, 24 per system with OpenVMS
V6.2-1H3. (End node only) Note: KFPSA and KFMSB not supported on the same bus.

BC21Q-xx

External shielded cable (MR/MR connectors) Select required length—09, 16, 25, 50 ft

BC22Q-xx

External shielded cable (MR/PS connectors) Select required length—16, 25, 50 ft

† Requires AlphaServer 8400 minimum System Console Firmware Revision V3.2.2, OpenVMS V6.2-1H2 and DIGITAL UNIX V3.2D

or later operating system software.

Summary of Contents for AlphaServer 8400

Page 1: ...mbination between these maximums with 1 2 GB sec peak of I O The AlphaServer 8400 5 440 supports up to 14 processors with 4 GB memory two processors with 28 GB of memory and any combination between th...

Page 2: ...Three CK KFTIA AA cabinet kits 256 MB 512 MB 2 GB or 4 GB of memory BA660 AB StorageWorks Plug in unit PIU 2 GB or 4 3 GB 3 5 SCSI system disk drive 600 MB CD ROM drive DWZZB VW SCSI signal converter...

Page 3: ...regulators Three Phase power subsystem includes power cord Shielded console cable for connection to console terminal Factory Installed Software 5 300 Operating System Software DIGITAL UNIX base licens...

Page 4: ...only no other disk or tape connections are supported maximum one per system BN21H 02 SCSI cable Required for XMI systems DWLMA AA XMI plug in unit See Step 6 for details KZMSA AB XMI single ended SCSI...

Page 5: ...es include processor module with Alpha microprocessor s SMP license and end user product warranty 5 300 Servers 5 350 Servers 5 440 Servers CPU Module Type Operating System 751P2 AX 753P2 AX N A Singl...

Page 6: ...three KFTHAs DWLPB AA PCI plug in unit with one PCI box for AlphaServer 8400 system cabinet only maximum two per system cabinet two per system Requires one I O channel connection on either KFTIA AA o...

Page 7: ...from KFTIA FWD port to DWZZB VW in BA661 AA in DWLPB xx PIU BN21K 03 Connects from KFTIA FWD port to DWZZB VW in BA660 AB System cabinet front BN21K 05 10 Connects from KFTIA FWD port to DWZZB VW in B...

Page 8: ...e ended SCSI cable for connections from PCI RAID controller to BA660 AB system cabinet and BA661 AA KZPSC UB Battery back up for cache memory option for KZPAC or KZPSC controller MS100 BB 8 MB cache m...

Page 9: ...A and OpenVMS V6 2 1H3 A DIGITAL UNIX patch OSF405 034 is required for dual redundant failover HSJ50 family of CI Storage Array Controllers are supported under OpenVMS V6 2 1H3 with CIPCA AA BA or CIX...

Page 10: ...rs and SCSI storage options Wide SCSI devices are supported in BA660 AB BA661 AA StorageWorks PIUs or external StorageWorks cabinets BA660 AB BA661 AA support both wide and narrow SCSI 5400 RPM and 72...

Page 11: ...w SCSI disk drive DS RZ40 VA 9 0 GB 7200 RPM 8 bit Narrow SCSI disk drive Tape Devices TLZ09 VA 8 0 GB DAT 3 5 SCSI tape drive in StorageWorks carrier OpenVMS V6 2 1H3 and DIGITAL UNIX V3 2C required...

Page 12: ...lers each with 32 MB cache HSZ Traditional License QL 2YJA9 AA RAID HSZ40 Firmware License QL 3J0A9 AA Mirror Firmware HSZ40 Traditional License QL 4DTA9 AA BN21K 20 20 meter cable BN21L 0B 15 meter c...

Page 13: ...nication Adapter OpenVMS v6 2 1H3 supports two per PCI maximum two per system PBXDA AB PCI Asynchronous 8 port Communication Adapter OpenVMS v6 2 1H3 supports two per PCI maximum two per system DE500...

Page 14: ...XI01 AA provides up to 48 additional ports DIGITAL UNIX only CXI01 AD Digiboard Asynchronous EPC X Multiport Serial Card with 16 RJ45 Port EPC CON 16 Concentrator uses one EISA slot DIGITAL UNIX one p...

Page 15: ...are at revision V2 3 or higher CCMAA BA Adapter must be installed in slots 0 7 of a DWLPA AA AB BA BB PCI no restriction for DWLPB AA AB BA BB PCI bus For two system nodes order one CCMAA BA per syste...

Page 16: ...gulator Provides space for two additional three phase power regulators H9F00 BA BB BC Rev D03 or later cabinets include the H7263 AC or H7263 AD non BBU capable power regulator Refer to Step 11 for ex...

Page 17: ...ry plug in unit with batteries for battery backup UPS capability maximum one per cabinet Use in system cabinet and or H9F00 BA BB BC expansion cabinet Includes four batteries to support 48 V power reg...

Page 18: ...ly Media available on layered product CD ROM KZMSA or KZPSA adapter required Included in 5 440 DIGITAL UNIX Base and Expanded Base Servers DIGITAL UNIX Media and Documentation QA MT4AA H8 DIGITAL UNIX...

Page 19: ...vers QA 5LVAA H8 DIGITAL Enterprise Integration Server for OpenVMS media and documentation DIGITAL NAS Base Server 200 Software DIGITAL NAS 200 Base Server software included with base 5 300 MHz AlphaS...

Page 20: ...ntal Support for DIGITAL UNIX two CPU systems FM 84DOS 36 36 month Software Supplemental Support for DIGITAL UNIX two CPU systems FM 84DOS 60 60 month Software Supplemental Support for DIGITAL UNIX tw...

Page 21: ...5 350 CPU modules 754P1 AX 754P2 AX 14 Additional dual 5 440 CPU modules 756P1 AX 756P2 AX 8 KFTIA AA System I O module 4 KFTHA AA System I O module 3 MS7CC BA 128 MB memory 5 MS7CC CA 256 MB memory...

Page 22: ...equal to value listed under operating system to be used 8 8 FDDI Options Included KFTIA AA I O module optional FDDI daughter card installed DEFPZ AA UA 1 Additional KFTIA AA I O module optional FDDI d...

Page 23: ...Channel BA655 PIU BA660 PIU Batteries for UPS Expansion Bay for XMI I O Channel PCI I O Channel BA655 PIU BA660 PIU Batteries for UPS System Cabinet I O Expansion Cabinet CD ROM Operator Control Pane...

Page 24: ...ewed to AS 3260 Australian Standard EN 60950 European Norm Power Requirements 1 Three Phase Power Subsystem 2 US Canada Europe AP Japan Nominal voltage Frequency range Phases Maximum input current pha...

Page 25: ...4N AEACM BK PUPS plus 15kVA receptacle module 2 L21 30R 3 5 20R2 4N AEACM BN PUPS plus 15kVA receptacle module 2 L6 30R 2 L21 30R 1 5 20R2 4N AEACM PA PUPS plus 15kVA dual receptacle module Module 1...

Reviews: