AlphaServer 8400
Alpha Servers 3.209
Step 1a—5/300 System Building Blocks
System Building Blocks are an alternative to standard Base Servers, or Expanded Base Servers. They provide flexibility in
configuring the AlphaServer 8400 with a choice of memory and I/O options.
System Building Block Requirements:
Minimum of one Memory module
Minimum of one I/O module
CD-ROM Drive
Systems require DIGITAL UNIX V3.2B or later, and OpenVMS V6.2 or later.
Console terminal required unless available on site.
System consists of 9 slot backplane—three slots used by CPU, memory, and system I/O modules.
- Six slots available for additional CPU, memory, or system I/O module(s).
If KFTHA-AA I/O module is selected the following PCI or XMI options must be ordered to provide the interface to
CD-ROM drive.
Required for PCI systems
DWLPB-AA
PCI plug-in unit. See Step 5 for details.
KZPAA-AA
PCI single-ended SCSI controller for CD-ROM connection only; KZPAA is restricted as CD-ROM
connection only, no other disk or tape connections are supported—maximum one per system.
BN21H-02
SCSI cable
Required for XMI systems
DWLMA-AA
XMI plug-in unit. See Step 6 for details.
KZMSA-AB
XMI single-ended SCSI controller
BN21H-02
SCSI cable
CD-ROM, 600 MB 5.25” in cabinet drive (RRDCD-CA) is required and must be ordered separately.
If Factory Installed Software is required, BA660-AB, appropriate disk drive, and controller must be ordered separately.
Redundant power supply (N+1) can be added if required.
AlphaServer 8400 5/300 System Building Blocks
Processor module with Two Alpha microprocessor
21164 5/300 MHz CPU(s), each CPU includes 4 MB
Backup cache
Three-Phase Power Subsystem with power cord
48 VDC power regulator
DIGITAL UNIX base license, or
OpenVMS base license
DIGITAL NAS Base Server 200 software
One year hardware product warranty
90 day software product warranty
Dual-CPU systems
Operating System
Power
Memory
I/O Module
DA-291BY-AA/AB/AC
DIGITAL UNIX
Three Phase
Required
Required
DY-291BY-AA/AB/AC
OpenVMS
Three Phase
Required
Required
Note: xA = 60 Hz, 208 V, xB = 50 Hz, 380/416 V, xC = 50/60 Hz, 202 V Japan
All Three Phase power variations include attached power cord.