3-2
Upgrade Manual
3.1 Restore System Information
After you have installed the new system drawer, turn on the system and check
the power-up test. Check the system configuration against the old
configuration. Insert the diskette and restore the system environment variable
settings and ECU data. Issue the set command to set the system model number
and serial number.
NOTE: You must type the commands exactly as they appear in Example 3–1.
Example 3–1 Restoring Environment Variables
P00>>> sho dev floppy
Ê
polling floppy0 (FLOPPY) PCEB - XBUS hose 0
dva0.0.0.1000.0 DVA0 RX23
P00>>> cat dva0.0.0.1000.0 -l 2200 >pmem:800000
Ë
P00>>> cat pmem:800000 >eerom
Ì
P00>>> cat pmem:802000 >toy
Í
P00>>> show *
Î
auto_action
HALT
boot_dev
boot_file
boot_osflags
boot_reset
OFF
[All environment variables are listed in output]
P00>>> set sys_serial_num NI49304561
Ï
P00>>> set sys_model_num 4100
P00>>> test
Ð