![Digital-Ally DTM-600 User Manual Download Page 51](http://html1.mh-extra.com/html/digital-ally/dtm-600/dtm-600_user-manual_2500320051.webp)
860-00324-00 Rev B 51
Table7-10
Parameter Description and Configuration
Parameter
Configuration
Protocol
Set it to
Wiegand 26
or
Wiegand 34
based on actual scenes.
Format
The options are as follows:
Ascending Order
The sequence of the card No. read by UNV card reader (EG121@IC)is the
positive sequence.
When the sequence is the same as the sequence of the card No. read by UNV
card reader, select
Ascending Order
in the input/output.
Descending Order
When the sequence is opposite to the sequence of the card No. read by UNV
card reader, select
Descending Order
in the input/output.
The default value is
Ascending Order
. Set this parameter based on actual scenes.
(3)
Click
Save
to complete the Wiegand interface configuration.
(3) IO Configuration
The face recognition terminal connects to gate machines, door locks, or access control buttons and sends the door
opening signal to them. Perform the following operations to complete configuration:
(1)
Choose
Setup
>
Common
>
Ports & Devices
and click the
IO Configuration
tab.
NOTE!
⚫
Some devices support the output from only one or zero IO ports and the IO port configuration
interface is different for the devices.
⚫
Some devices does not support door locks or access control buttons and the IO port configuration
interface is different for the devices.
Figure7-24
IO Configuration Interface
(2)
Configure IO port information by referring to the table below.