background image

LCD Keypad

DGP2-641

System Manager’s Manual

Also includes

Operating Instructions

Summary of Contents for DGP2-641

Page 1: ...LCD Keypad DGP2 641 System Manager s Manual Also includes Operating Instructions ...

Page 2: ......

Page 3: ... 13 How Access Control Works 14 TROUBLE DISPLAY 15 Event Record Display 16 ADDITIONAL FEATURES 16 Programmable Outputs PGMs 16 Keypad Settings 16 Set Time Date 17 Programming Chime Zones 17 Panic Alarms 17 Quick Function Buttons 17 TESTING AND MAINTENANCE 18 Burglar Alarm Testing 18 Fire Alarm Testing 18 System Maintenance 18 System Test 18 FIRE AND BURGLAR ALARMS 18 Standard Fire Zone 18 Delayed ...

Page 4: ...plexNE InTouch WinLoad and NEware are trademarks or registered trademarks of Paradox Security Systems Ltd or its affiliates in Canada the United States and or other countries All rights reserved Specifications may change without prior notice ...

Page 5: ...BASIC OPERATION The following sections will introduce you to the roles of the buttons lights and messages on your LCD keypad Figure 2 1 Basic Overview 2 1 AUDITORY FEEDBACK BEEP TONES When you enter information on the keypad the keypad will guide you with beep tones to communicate the acceptance or rejection of your entries Confirmation Beep When an operation i e arming disarming is successfully e...

Page 6: ...lay mode the following information will scroll on the LCD screen ready if all zones in the selected area are closed not ready if zones in the selected area are open open zones within that area i e Front Door Open Trouble s section 7 0 on page 15 if a trouble has occurred Alarms in Memory section 4 3 on page 7 if an alarm has occurred Armed Force Armed Instant Armed Stay Armed displays the arming s...

Page 7: ...rm refer to section 2 3 on page 4 Force arming allows you to quickly arm your system when zones are open However once the open zone is closed your system will then arm that zone as well How do I Force arm 1 Enter your ACCESS CODE 2 Press the FORCE button 3 If you have access to more than one area select the area s you wish to Force arm refer to section 2 3 on page 4 You can bypass certain zones wh...

Page 8: ...ISARMING When your system is disarmed it deactivates any alarms in progress and it deactivates the zones so the alarm will not be triggered if zones are breached 4 1 ENTRY DELAY TIMER Your installer will program designated entry points i e the front door with an Entry Delay Timer This delay gives you time to enter the armed premises and enter your code to disarm your system before the alarm is tri...

Page 9: ...anually changed the System Master Code will immediately revert to its original programming You can assign a label name to a User Access Code at any point during the programming User Access Code process Refer to section 5 4 on page 8 to assign a User Label You can only disarm an area to which your User Access Code is assigned User Access Codes with the Arm Only section 5 7 on page 12 option enabled...

Page 10: ...other All User Options are copied except the User Code Card Assignment and User Label How do I copy user options 1 Enter your ACCESS CODE System Master Code or User Access Code with Master feature 2 Press the 0 button and then the ACC button 3 Enter the 3 digit User Number you wish to copy TO 4 Press the MEM button 5 Enter the 3 digit User Number you wish to copy FROM 6 Enter a User Code If the Us...

Page 11: ...mbers 0 to 9 BYP Lower Case Upper Case Every time the BYP key is pressed it will toggle the case setting from lower to upper case and vice versa MEM Special Characters After pressing the MEM key the cursor will turn into a flashing black square Using Table 2 on page 9 enter the 3 digit number that represents the desired symbol If using a Hebrew keypad refer to Table 5 in Appendix 1 Hebrew Special ...

Page 12: ...u press ACC Enter the 3 digit User Number you want to program press the T button to scroll the list of codes and then press ACC once the desired code appears on the screen or to Find Next Free User press the BYP button refer to section 5 2 on page 8 Enter a User Code within the brackets If the User Code is of variable length press the ENTER button after entering the User Code Press the S button to...

Page 13: ...s Control Doors is Access Level 00 B Enter the 2 digit Schedule i e 00 01 15 in the second set of brackets Schedules programmed by your Installer determine the hours days and holidays that Users are permitted through Access Control Doors Each user is assigned a Schedule through the User Access Code To provide access at all times assign Schedule 00 Program the Access Control User Options by pressin...

Page 14: ... assigned areas Option 7 Force Arm When option 7 is ON the Force arm feature is enabled The User can now Force arm their assigned areas Option 8 Area Access When option 8 is ON the keypad will permit access to all the areas assigned to the User Access Code When option 8 is OFF the keypad will only permit access to the areas it controls For example the keypad is assigned area 1 only and your User A...

Page 15: ... the armed area When option 8 is OFF a User can gain access to an Access Control Door only if the door s area s is already disarmed For option 8 to function in the ON position option 5 Arm Only in the User Options must be disabled refer to section 5 7 on page 12 6 0 USING ACCESS CONTROL 6 1 ENTERING EXITING Depending on how your system is installed there are various ways to enter and exit Access C...

Page 16: ...door during its assigned Schedule refer to step 8 in Figure 5 1 on page 10 presented to a door within its assigned Access Level refer to step 8 in Figure 5 1 on page 10 programmed to allow disarming option 2 in section 5 8 on page 12 assigned to all areas that are assigned to the Access Control Door refer to step 7 in Figure 5 1 on page 10 or assigned to at least one of the areas assigned to the A...

Page 17: ...ler for repairs Battery Trouble The backup battery is disconnected needs to be recharged or replaced Bell Absent The system has detected that the bell or siren is not connected 7 0 2 GROUP 5 ZONE TAMPER The zone s that was tampered with will be displayed on the LCD screen 7 0 3 GROUP 6 ZONE LOW BATTERY If a wireless device s battery needs to be replaced the zone that is assigned to the device will...

Page 18: ...You can modify the keypad settings to suit your needs Refer to Figure 8 1 on page 16 1 Scrolling Speed refers to the amount of time that a message will remain on the screen before moving to the next message 2 Backlight refers to the illumination behind the buttons and LCD screen 3 Contrast refers to how dark or pale characters will appear on the screen Figure 8 1 Modifying LCD screen settings The ...

Page 19: ...ller can also program your Chime zones to beep upon closure How do I program chime zones 1 Enter your ACCESS CODE 2 Press the 9 button 3 Press the 1 button to chime a zone Enter the number corresponding to the zone to be chimed or use the S and T buttons to scroll the list of zones Press the ACC button to chime or unchime the zone that appears on the screen Press ENTER to save OR Press the 2 butto...

Page 20: ...aneously press and hold the CLEAR and ENTER buttons for two seconds Speak to your Installer before conducting a System Test since the system must be programmed to respond to the test instructions It is normally recommended that you conduct the system test once a week but contact your Installer for instructions concerning your particular system How do I conduct the system test 1 Call your Central M...

Page 21: ...ng the way out with eyes closed Instruct everyone never to stand up during a fire always crawl under the smoke and keep mouths covered Instruct everyone never to return to a burning building for any reason it may cost them their life Check smoke alarms regularly Working smoke alarms dramatically increase everyone s chances of surviving a fire If the zone is a Delayed Fire Zone there is an automati...

Page 22: ...ing cause of residential fires 10 5 HOME FIRE WARNING SYSTEM Household fires are especially dangerous at night Fires produce smoke and deadly gases that can overcome occupants while they sleep To warn against fire smoke detectors should be installed outside each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basemen...

Page 23: ...ey after entering your User Access Code STEP 3 Keys 1 to 8 on your telephone represent areas 1 to 8 To arm or disarm your DigiplexNE system press the desired area s number on your telephone This will toggle the area s arming state from armed to disarmed and vice versa refer to section 16 0 on page 22 STEP 4 To activate or deactivate the InTouch s output press the key and then the 0 key refer to se...

Page 24: ... your telephone Hang Up 9 When you wish to hang up press the button and then the 9 button to immediately hang up The InTouch will confirm the hang up with Good bye If the hang up feature is not used and if no action is performed after 2 minutes the InTouch will hang up automatically 16 0 INTOUCH EXAMPLE Nelson has a DigiplexNE system and an InTouch hooked up at home His security system has two are...

Page 25: ... output which in turn will activate the garage door The InTouch then prompts Nelson with the following Output is Activated Nelson then presses the key and then the 9 key on his telephone to terminate the call The InTouch then prompts Nelson with the following Goodbye 17 0 INTOUCH SYSTEM CHECKLIST Telephone Number _____________________ Output Activates _______________________ Output follows N Outpu...

Page 26: ...bles when programming the user labels of a Hebrew keypad Instead of using Tables 1 and 2 pages 8 and 9 use Tables 4 and 5 below Refer to section 5 4 on page 8 for information on programming user labels Table 4 Hebrew Keypad Letter Assignment Table 5 Hebrew Special Characters Catalogue ...

Page 27: ...es when programming the user labels of a Russian keypad Instead of using Tables 1 and 2 pages 8 and 9 use Tables 6 and 7 below Refer to section 5 4 on page 8 for information on programming user labels Table 6 Russian Keypad Letter Assignment Table 7 Russian Special Characters Catalogue ...

Page 28: ...hime Zones Rejection beep 3 Bell Disconnected 15 Burglar Alarms 20 Buttons One Touch 6 Quick Function 17 Bypass Bypass Recall 5 Programming 5 C Card Access Control Activating 12 Arming with 13 Assign 11 Disarming with 14 Characters Special 9 Chime Zones 17 Clock Set Time and Date 17 Code Follows Schedule 13 Confidential Mode 4 Copy User Options 8 D Date Set 17 Deactivating a Security System 6 Dela...

Page 29: ...ones 5 Regular Arming 4 Request for Exit 13 Russian Special Characters 25 S Safety Tips Fire 19 Schedule Code Follows 13 Schedule Tolerance Window see Add Tolerance to User Sched ule Schedules 11 Search Next Available Code 8 Separated System see Partitioned System Siren Disconnected 15 Special Characters 9 Special Characters Hebrew 24 Special Characters Russian 25 Special Function Keys 9 Standard ...

Page 30: ...may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expressly limited to repairing or replacing at Seller s option any product not meeting the specifications In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether dire...

Page 31: ......

Page 32: ...PRINTED IN CANADA 06 2003 DGP2NE641 EU03 ...