7
H.264 Indoor/Outdoor Dome IP Camera
SECTION 2: INSTALLATION AND SETUP
2.4.2 Sensor in (DI) connection
The camera provides one channel for sensor input that can be connected to either a voltage type or relay type sensor. For voltage
type sensors, the camera allows a maximum input of 24 V DC, with a 1 V DC threshold (see Specifications). The configuration of the
sensor input wiring is illustrated in the diagrams below.
CAUTION
Do not exceed the maximum input voltage or the relay switching rate. Refer to the specifications in this
manual for more information.
Voltage type sensor wiring schematic
Relay type sensor wiring schematic
To connect a sensor to the camera:
1.
Route sensor wiring through the cable channel and into the camera base housing.
2.
Strip 1/4” of insulation from the sensor wires and insert them into the terminal block in the DI pin locations shown above.
The pin marked “C” in the terminal block is the common (COM) pin.