background image

Push Button Minute Timer 

Timer Setup 

The LEDsmart

+

 push button timer has a number of useful functions which can easily be set up by entering setup mode and

following the four easy steps. 

The TIMEOUT PERIOD should always be set up. The other settings are optional, depending on the application.  To set the 
timeout period now, go to the next page. 

Timer Setup Functions 

Function 

See Part 

Setting the 

Timeout

 

period

 

Setting 

Maximum Brightness

 

Setting 

Advanced Timer Features

 

Setting 

Off State LED

 

Feature

 

Converting from minute to hour 
timer 

Setting 

MultiMate™ Mode

 

Factory Defaults 

Reset

 

A: Entering Setup Mode 

If the timer has been powered up for 

LESS THAN 15 MINUTES

 see 

A1

If the timer has been powered up for 

MORE THAN 15 MINUTES

 see 

A2

Once in Setup Mode, options are selected by a series of ‘clicks’ of the push button. Each ‘click’ should be within 1 second 
of the previous click.    

Summary of Contents for LEDsmart+ MultiMate MMTM/PB

Page 1: ...Setup Functions Guide MMTM PB www glg lighting Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi way control...

Page 2: ...mer Setup Functions Function See Part Setting the Timeout period A Setting Maximum Brightness B Setting Advanced Timer Features C Setting Off State LED Feature D Converting from minute to hour timer E...

Page 3: ...o be adjusted as required Go to the relevant setup function instructions A2 Timer has been powered up via mains 240Vac for MORE THAN 15 MINUTES Step 1 Press and hold the button for 30 seconds Note Thi...

Page 4: ...othing for 30 seconds Step 4 To set the time out interval push and hold the button and count the number of blinks Each blink of the indicator adds 1 minute to the minute timer Step 5 When the number o...

Page 5: ...ep 1 Enter into the timer Setup Mode See PART A Step 2 Click the push button 3 times Step 3 The LED Indicator will blink 3 times Note To cancel exit do nothing for 30 seconds Note If more than one dim...

Page 6: ...tep 2 Click the push button 4 times Step 3 The LED Indicator will blink 4 times Note To cancel exit do nothing for 30 seconds Step 4 To enable the advanced timer mode Push and hold the button until th...

Page 7: ...n the timer is off follow the steps below Step 1 Enter into the timer Setup Mode See PART A Step 2 Click the push button 5 times Step 3 The LED Indicator will blink 5 times Note To cancel exit do noth...

Page 8: ...Enter into the timer Setup Mode See PART A Step 2 Click the push button 6 times Step 3 The LED Indicator will blink 6 times Note To cancel exit do nothing for 30 seconds Step 4 To change operation to...

Page 9: ...s connected to the dimmer will now turn OFF b If the MultiMate function is currently Enabled lamps s connected to the dimmer will now turn ON Note To cancel exit do nothing for 30 seconds Step 4 To En...

Page 10: ...Button Minute Timer 10 H Resetting to Factory Default Step 1 Enter into the timer Setup Mode See PART A Step 2 Click the push button 10 times Step 3 The timer will automatically exit Setup Mode once r...

Page 11: ...ment to Gerard Lighting Gerard Lighting Pty Ltd Gerard Lighting reserves the right to alter the specifications designs or other features of any items and to discontinue any items at any time without n...

Page 12: ...hing of connected lighting loads from multiple locations without any additional wiring No strapper wires dedicated remote switch wiring or control bus is required HOW MULTIMATE WORKS MultiMate product...

Page 13: ...higher value Refer to the product installation guide for details Solution 2 Fit a load bypass device order code MMBP Solution 3 In extreme cases both the MMBP and a raised minimum level may be needed...

Page 14: ...own transformer to building High resistance terminations on active feeds and or neutral returns and Neutral returns from a common active feed having significantly different run lengths back to the swi...

Page 15: ...mable LED load may be used on the same circuit as non dimmable loads In this case when the dimmer level is higher than a threshold the relay is operated to switch the non dimmable load s on and the di...