background image

 Keypad Interface

Flex Key Managed - E Function

Shared Use Functionality

Product Guide

Phone: 707 766 6000

www.digilock.com | [email protected]

PG-NLRK-E-DEN

Support

Battery Replacement

5

Sleep Mode

After three consecutive incorrect User Code entries to unlock, the lock will go into Sleep Mode for one minute. For each subsequent incorrect 

entry, the lock will remain in Sleep Mode for an additional minute. The keypad is disabled while in Sleep Mode. A valid Manager Flex Key may 

be used to unlock while the lock is in Sleep Mode. 

Error Condition Indicators

10 rapid beeps:

The lock is binding, meaning either door alignment or items in the locker are preventing the lock from operating. Press on the door while 

operating the lock. If error condition persists, contact Digilock support for assistance.

2 sets of three beeps:

The batteries are low. Replace the batteries.

Does not Unlock with the User Code or User Key

The lock does not recognize the User Code or User Key. For immediate access, operate with a valid Manager Flex Key.

Does not Operate with a Manager Flex Key

The lock does not recognize the Manager Flex Key. Contact Digilock Support. For immediate access, operate with another valid Manager Flex 

Key.

No Audible Feedback when 

=

 is Pressed

 

The lock may be in Sleep Mode or the batteries may need to be replaced. For immediate access, operate with a valid Manager Flex Key. 

 

The front unit may not be properly connected to the rear unit. Remove the lock from the door and check the connection.

041719

It is not necessary to remove the lock from the door. In case of battery failure, operate with a valid Manager Key.

CAUTION: Risk of explosion or leakage if battery is replaced by an incorrect type, mixed with a different battery type, or inserted backwards. 

Replace all batteries of a set at the same time. Be sure to insert batteries with correct polarities. Remove exhausted batteries from product 

promptly and dispose of used batteries according to the battery manufacturer’s instructions.

Remove the screw from the Cover Plate 

with a Phillips head screwdriver.
Remove the Cover Plate by lifting the tab at 

the edge of the cover, below the arrows.

Remove the batteries from the housing.
Replace with four premium alkaline AA 

batteries. Dispose or recycle used batteries 

according to local regulations.

Replace the Cover Plate and secure with 

the screw.

1

2

3

Reviews: