Page 4: ...r kit 14 6 3 Power supply 16 6 4 Control board 17 6 4 1 Inputs 20 6 4 1 1 Connection scheme 21 6 4 1 2 Pictogram 21 6 4 1 3 Pictogram s connections 21 6 4 2 Configuration of control board Switch Ds1 2...

Page 5: ...tes something Digicon considers important CAUTION Indicates a moment of extreme caution when handling the equipment product ATTENTION Indicates a moment when your observation skills should be extremel...

Page 6: ...e information in this manual and cannot be held responsible for errors it may contain and problems due to its use The information contained in this manual is exclusive property of Digicon and is prote...

Page 7: ...nal holes Access to the support is done through a key with secret whose removal and insertion are extremely easy A plastic cover and a stainless steel sheet compose the upper panel The cover made of i...

Page 8: ...inputs depending on the passage direction If this signal is recognized the equipment will allow the turning of the arm of C Fit After half of the turning is complete 60 degrees a 400 milliseconds atra...

Page 9: ...uring inspection accompanies all Digicon packages See below the parts that can compose C Fit atrax ATTENTION To avoid losses the screws and the wrenches used for assembling the C Fit are attached to t...

Page 10: ...panel and plug s locks for the cables passage if there will be enough space for the arms after C Fit is assembled atrax If the floor is in conditions to receive anchor bolts minimum of 4 cm of FCK15 M...

Page 11: ...t 25mm of the bolt out of the hole 4 Position the column and fasten it to the floor with the four screws that accompany the bolts Use a flex head socket wrench with or an articulated socket wrench 5 4...

Page 12: ...interior of the equipment can be done with the key that accompanies the equipment 5 5 1 Cover 1 Open the lock with the smaller key clockwise 2 Unscrew the two screws in the turnstile s front 3 Pull t...

Page 13: ...y however Digicon offers a range of optional items that allow enhancing and matching the equipment s performance to the client s needs See the description of each of these items 6 1 Pictogram kit The...

Page 14: ...pulses like the other counters available in the market The Digicon electronic counter works through a key button that allows access to all its functions Optionally there is the possibility of the ins...

Page 15: ...n of partial counter Visualization of total counter Resetting the partial totalizer To reset the partial totalizer it is necessary to access the partial visualization mode and then press the function...

Page 16: ...and environmental conditions which ensures the adequate power supply to the equipment s performance Besides the input and output voltages indicated in the image below the supply has a short circuit an...

Page 17: ...ket The controller have mechanical features and layout perfectly suited for the C Fit s needs and it is one of the best options for the equipment s atrax operation The following image shows the contro...

Page 18: ...ht 10 CLOCK2 input for reader from right to left 11 DATA2 input for reader from right to left 12 GND CN2 OUTPUTS 1 NO or NC Contact HAB1 return 2 Contact C HAB1 return 3 NO or NC Contact HAB2 return 4...

Page 19: ...signal 3 GND 4 GND CN5 ELECTROMAGNETS electromagnet 1 electromagnet 1 electromagnet 2 electromagnet 2 CN6 OPTICAL SENSORS Sensor 1 signal LED 1 anode Sensor 2 signal GND LED 2 anode INFORMATION The c...

Page 20: ...220 V c c d ac d To enable passage through relay contact or pushbutton make the connection as shown below Enabling passage through tension pulse is shown in the image below It is necessary to observe...

Page 21: ...s maximum 500 mA at the moment of activation the GND is sent through a corresponding output 6 4 1 3 Pictogram connections 21 INPUTS INPUTS OUTPUTS RALAY ACCESS CONTROL BOARD OUTPUTS DIGICON CONTROL BO...

Page 22: ...ning there is no mechanical wear and two opto isolated inputs for liberating Catrax Fit if necessary 6 4 3 Outputs The C Fit board presents outputs for return signals electromagnets pictograms atrax c...

Page 23: ...brasion between the coil and the locking device avoiding malfunctions Moreover the activation is done through a transistor and not a relay avoiding the electromagnet to be blown due to the contact wie...

Page 24: ...tion always cleared and when the HAB2 clockwise clearance signal is received clear passage for counter undetermined period 3 Configuration of controller to clear the turning while the relay has the co...

Page 25: ...m raised during normal operation In case of power outage when the installation has no no break or through a command sent via system or the activation of an emergency button in the control room the ele...

Page 26: ...0 8Vcc non obstructed sensors With the pointers at the same position force the equipment s arms to both directions in one of the sides the voltage should be higher than 4 5V c d Repeat the same operat...

Page 27: ...es To check for the need of corrective actions you must check the lock s correct position check the wear of the lock s fitting to the sprocket Corrective actions 1 if the lock s position is incorrect...

Page 28: ...net turnstile cannot be locked The cable is broken or the distance between the electromagnet and the locking device is maladjusted Adjust the electromagnet or forward the equipment to the Technical As...

Page 29: ...8 Technical characteristics 8 1 Dimensions 29 730 28 740 93 3 661 860 33 585 1000 39 370 685 26 968 210 8 267...

Page 30: ...Electromagnets power 12 Vcc and 12 A Sensors power 5 Vcc and 0 5 A Power supply optional Input 100 Vac and 240 Vca Output 12 Vac 5 3 A Dimensions 35 x 51 x 105 mm Distance between holes 43 x 98 cm Dia...