INFORMATION
: The turning of the turnstile can be blocked only with the
activation of the electromagnets. If the turnstile has no power supply, the
turning mechanism remains free.
4.1 C
Fit Operation
atrax
In the basic mechanism, C
Fit has a two-dimensional rotation system with two
atrax
12 V electromagnets for activating the locks and two optical sensors that can provide
the signal for the activation of the electromagnets and passage clearance.
In the electronic model, which includes a microprocessor control board (optional), a
signal enabling passage is sent through one of the inputs, depending on the passage
direction. If this signal is recognized, the equipment will allow the turning of the arm
of C
Fit. After half of the turning is complete (60 degrees), a 400 milliseconds
atrax
returning signal will be sent, informing the passage direction. After the signal, the
arm cannot be returned to the previous position.
Depending on the C
Fit model and configuration, if the passage is forced without
atrax
the enabling signal, an electromagnet will be activated to prevent turn. In addition,
the equipment can emit a signal for a sound alarm and/or the exhibition of a red X on
the upper panel display (models with pictogram). In this case, a return signal will be
sent, indicating that the turnstile was forced, informing the direction of turn.
-Mechanisms of C
Fit:
atrax