background image

 

Operation 

D3655-US Rev E 

EZ400 User’s Manual 

Print Formats 

Three print formats are available to output 

PRTACC 

value and 

SCALE ID 

to DDL 

or printer.   

PRTAC1:

  

FIELD ID,   4856, GR, 274575, PA, 05FE08, I:44P

 

PRTAC2:

 

FIELD ID, 05FE08, I:44P

 

  

 

4856, GR, 274575, PA

 

Includes following information: 

  Scale ID (

SCALID

 Weight 

  Weight Tag (Net, Gross, Load/Unload) 

 Accumulated 

Weight 

  Print Accumulator Tag 

 Date 

and 

Time 

 

PRTAC3:

 

FIELD3, 5977, LB, ,GR, 3097I9,PA,05FE08, 4:42P

 

Includes above and adds “Unit of Measure” and “Lock-On Status” (for 

animal weighing). 

 

See “Setting Options” (page 13) to change print format (

PRTFMT

). 

 

All manuals and user guides at all-guides.com

Summary of Contents for EZ400

Page 1: ...D3655 US REV E February 09 2010 EZ400 Operators Manual Ft Atkinson Wisconsin USA Panningen The Netherlands www digi star com HELLO All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...EZ400 User s Manual D3655 US Rev E All manuals and user guides at all guides com...

Page 3: ...11 Lock on Weigh Method 4 11 WEIGHING ERRORS 12 Over Capacity Limit OVRCAP 12 Over Range RANGE 12 Under Range RANGE 12 Low Battery Indication LO BAT 12 RUN SELF TEST 12 MENUS AND CALIBRATION 13 Changi...

Page 4: ...written permission is forbidden The contents of this manual are subject to change without notice All efforts have been made to assure the accuracy of the contents of this manual However should any err...

Page 5: ...circular connector Gold contacts POWER REQUIREMENTS 10 5 to 16 0 V D C 160 mA nominal with four 350 L C SET UP AND CALIBRATION Via front panel GROSS RANGE 999 999 max display LOW BATTERY WARNING Enabl...

Page 6: ...an the indicator Charging Battery and Welding Disconnect all cables from the weighing indicator before charging the battery or welding on the machine If cables are left connected the weighing indicato...

Page 7: ...ndard EZ400 Optional EZ400 with serial port temporary zero Net Mode printer records to memory or prints displayed weight 3 toggles between Net and Gross weights 4 turns indicator on off Press while on...

Page 8: ...05 Optional to communicate with computer and other digital Input Output devices 9 Remote Port Optional for remote display Pin J905 Connector Signals 1 5VDC 2 Com 1 Out Tx Computer 3 Com 1 In Rx DDL Co...

Page 9: ...TION Turn on Indicator Zero Balance Indicator 1 Press 1 Press for 3 seconds to zero balance indicator 2 Flashing arrow points to gross next to the display window indicator ready to weigh 1 H E L L O 1...

Page 10: ...mporary zero Net Weight to display total weight Gross Weight Press 1 Weight displayed press sets zero weight 2 Pressing displays zero weight and flashing arrow on side of display points to NET 3 Add m...

Page 11: ...otal of original weight of 4000 pounds plus added 300 pounds press to show 4300 pounds flashing arrow points GROSS 5 Press 300 pounds displayed flashing arrow points NET 4 5 4 3 0 0 3 0 0 All manuals...

Page 12: ...ct the DDL to the SERIAL port on the bottom panel See page 4 2 Press and hold to save print data to the DDL 1 Press and hold 3 seconds to send displayed weight to serial port Each time this command is...

Page 13: ...ID 05FE08 I 44P 4856 GR 274575 PA Includes following information Scale ID SCALID Weight Weight Tag Net Gross Load Unload Accumulated Weight Print Accumulator Tag Date and Time PRTAC3 FIELD3 5977 LB G...

Page 14: ...icator 1 Press and hold 3 seconds SCALID is displayed followed by current ID name 2 Use and to enter new Scale ID 3 Press to view accumulated weight 4 Press to resume weighing Or 5 Press to clear accu...

Page 15: ...table accurate weight Set to OFF for weighing stable weights Lock On sensitivity can be adjusted using LOCKON menu Once weight displayed scale Locks On to weight Weight does not change even if motion...

Page 16: ...on the calibration zero and display count size Under Range RANGE The display shows the message RANGE if the weight on the scale system is less than the minimum weight measurable by the scale system Th...

Page 17: ...turn to indicator operation Default settings from the factory vary with options and due to customer preferences SETTING display OPTIONS displayed BOLD DEFAULT DESCRIPTION MENU 1 BASIC FEATURES IN MOST...

Page 18: ...ivity LOCK ON STORE LSTORE For animal weighing only LOCK ON STORE SEND LSSEND For animal weighing only 1 PRESS ZERO I zero ON OFF If ON press and hold Zero key to Zero Balance scale MENU 2 CLOCK PRINT...

Page 19: ...200 A 3200 B 32 TMR DATCHI FDINFO WTRCTM EIDINF EID EIDVID PRTAC1 PRTAC2 PRTAC3 Select alternate comma CSV formats zerout CI DLY OFF I0 25 50 75 I 5 Choose the number of seconds the printer will delay...

Page 20: ...M1 ADJUST 1 wmaI I Enter MAXIMUM weight measurable on scale WM1 ADJUST 2 wmaI 2 0 OFF Use values less than WMA 1 1 for quick weight response WM1 ADJUST 3 wmaI 3 Enter weight to activate quick weight r...

Page 21: ...Number Write down current SETUP and CAL numbers of your EZ 400 indicator These numbers are displayed during Self Test SETUP NUMBER To run self test with indicator ON 1 Press then to start Self Test 2...

Page 22: ...known value For best results you should have at least as much weight as largest load you plan to weigh Determining New Setup and Calibration Numbers The setup number does not change 1 Press to Zero Ba...

Page 23: ...th the right digit flashing 3 Press several times to increment digit to it proper value 4 Press to advance digit left Repeat steps 3 and 4 for each digit as required 5 Press to enter new setup number...

Page 24: ...0 BRACKET WING MOUNT D 405069 U BOLT 1 4 20 X 3 25 ZP E 403771 MODIFIED PLASTIC WEDGE MOUNT F 405124 WEDGE MOUNT BRACKET INCLUDES U BOLTS NUTS G 405084 NUT 1 4 20 TOP LOCKING FLANGE Optional Ram Mount...

Page 25: ...le Connections Scale Indicator Remote Indicator Optional See J Box Connections Power Cord J Box Connection Serial J905 Optional Remote Port Optional Power Cord Connection PinTo 12VDC Power Supply 1 Re...

Page 26: ...y need to change Refer to calibration procedures see pages 17 19 or contact your Digi Star representative for assistance Connect load cell wires to terminal blocks See Wire Color Key J Box Illustrated...

Page 27: ...oader Allows transfer of data from indicator to PC Optional Serial J905 port must already be installed in indicator RD440 small remote display RD2400V backlit remote display with 1 7 high numbers RD24...

Page 28: ...ng a multimeter to check for voltage measure between pin 1 pos and pin 2 neg Meter should read between 10 5 and 14 5 volts DC if using a tractor power cord black wire is positive and white wire is neg...

Page 29: ...how much weight is over each Load Cell In general the number should be positive and stable 5 Stand or hang your weight over the connected Load Cell Record how much the weight increased with your weigh...

Reviews: