EVERY 2500 HOURS OR 12 MONTHS
•
Change gear oil in planetary.
Escaping fluid under pressure can have sufficient force to
penetrate the skin causing serious personal injury. Fluid escaping
from a very small hole can be almost invisible. Use a piece of
cardboard or wood, rather than hands to search for suspected
leaks.
Keep unprotected body parts, such as face, eyes, and arms as far away as possible
from a suspected leak. Flesh injected with hydraulic fluid may develop gangrene or
other permanent disabilities.
If injured by injected fluid, see a doctor at once. If your doctor is not familiar with this
type of injury, ask him to research it immediately to determine proper treatment.
IMPORTANT: When replacing parts use only factory approved replacement parts.
Manufacturer will not claim responsibility for use of unapproved parts or accessories
and/or other damages as a result of their use.
PICK REPLACEMENT
Picks should be replaced if you are changing to a different application pick, they are
broken, worn, flat spot or are seized in the pick holder and do not rotate freely.
Always wear safety glasses with side shields when striking metal.
Failure to heed could result in serious injury to the eyes or other
parts of the body.
Do all pick maintenance through access door.
DO NOT attempt to check the picks with the planer in a raised
position without first blocking the planer. Before exercising the MANDATORY
SAFETY SHUTDOWN PROCEDURE find an elevated surface to set the
planer on or have a second person block the planer in place before shutting
down the machine.
1. Open front access door.
2. Rotate the drum until the pick to be removed is conveniently accessible.
3. Hold the extracting tool (pick puller) in one hand and place the jaws in the groove
of the pick, with the offset handle pointing away from the pick holder.
Profila Operator’s Manual Maintenance and Service
19