NOTE:
V1 on the bottom of the housing where the wires enter the controller.
3. Attach the controller into place on the top of the solenoid (see ).
2.3 Maximum Wire Run
100’ (30 m) using 18 AWG (0.75 mm) solid core direct burial irrigation wire
200’ (60 m) using 14 AWG (2.5 mm) solid core direct burial irrigation wire
300’ (90 m) using 12 AWG (4 mm) solid core direct burial irrigation wire
3.
Initial LEIT-2ET Connection
3.1 Connecting to a lEIT-2ET controller for the first time
NOTE:
Prior to initial LEIT-2ET connection, LEIT RC2ET handset Client ID must be
set at AAA (factory default setting).
In order to begin communication with a new LEIT-2ET controller using the handset,
a series of initial setup steps must be made. First, the user connects to the LEIT-
2ET controller via CONTROL ID 00 DEFAULT SETUP. Next, the user must assign
the controller a new Control ID (recommended ID # 2-99). At this stage, the user
can also change the existing Client ID of the controller (controller default Client
ID is AAA) as long as it is also changed on the handset after exiting the controller
program. In addition a descriptive controller address or name can be assigned to
the controller with up to 14 characters to uniquely identify the location of each
LEIT-2ET controller on the system.
Step 1:
Make sure the LEIT-2ET controller is out in bright light to harness light
energy used to power the controller. It will take about 30 minutes, or less, in direct
sunlight.
Step 2:
Splice the two (2) yellow (or yellow and black) sensor wires together using
waterproof connectors. This splice will indicate that the controller is ready to
communicate with a LEIT RC2ET remote control handset.
Step 3:
Connect via RADIO UPLINK screen:
a. On the LEIT RC2ET remote control handset’s MAIN MENU, press and highlight
RADIO UPLINK icon. Press again, and CONTROL ID: 00 DEFAULT SETUP
with the first Ø blinking appears. Press again to connect. ARE YOU SURE?
screen appears with RADIO UPLINK icon selected. Press again to connect.
18
d