CMi4160
– LoRaWAN
®
Module
15
02/2021
Figure 8: Structure, message format Scheduled
– daily redundant
DIB
Field
Size
Data type
Description
0
Message
format
identifier
1 byte
-
0x21 (Scheduled-daily redundant)
1
Energy
6-7 bytes
INT32
Energy consumption (Wh, J, Cal)
0403xxxxxxxx = xxxxxxxx Wh
0404xxxxxxxx = xxxxxxxx * 10 Wh
0405xxxxxxxx = xxxxxxxx * 100 Wh
0406xxxxxxxx = xxxxxxxx kWh
0407xxxxxxxx = xxxxxxxx * 10 kWh
040Exxxxxxxx = xxxxxxxx MJ
040Fxxxxxxxx = xxxxxxxx * 10 MJ
04FB0Dxxxxxxxx = xxxxxxxx MCal
04FB0Exxxxxxxx = xxxxxxxx * 10 MCal
04FB0Fxxxxxxxx = xxxxxxxx * 100 MCal
2
Volume
6 bytes
INT32
Volume (m
3
)
0413xxxxxxxx = xxxxxxxx * 0.001 m
3
0414xxxxxxxx = xxxxxxxx * 0.01 m
3
0415xxxxxxxx = xxxxxxxx * 0.1 m
3
0416xxxxxxxx = xxxxxxxx m
3
0417xxxxxxxx = xxxxxxxx * 10 m
3
3
Meter
address
10 bytes
According to
M-Bus
EN13757-3
identification
field
Meter address
Byte 0-1 = DIF/VIF code
Byte 2-5 = Meter ID, BCD8
Byte 6-7 = Meter manufacturer
Byte 8 = Meter version
Byte 9 = Device type
4
Error flags
4 bytes
INT8
Error and warning flags
01FD17xx
For further information about Error
flags please refer to the meter’s user
guide
5
Meter
date/time
6 bytes
INT32
Meter date and time (YY-MM-DD
HH:MM)
046Dxxxxxxxx
Bit 31-28 = Year-high*
Bit 27-24 = Month
Bit 23-21 = Year-low*
Bit 20-16 = Day
Bit 15 = Summertime flag**
Bit 12-8 = Hour
Bit 7 = Error flag***
Bit 6 = Reserved for future use***
Bit 5-0 = Minute