CMi4160
– LoRaWAN
®
Module
8
02/2021
Table 2 provides a summary of all parameters and settings in CMi4160.
Field
name
(Abbr.)
Description
Default value
Device
access
Locked device
& correct
Product Access
Key
or
Open device
Device
access
No
Product
Access
Key
Downlink
Meter ID
Meter identification
number of the meter.
Not configurable.
N/A
Readable
Readable
N/A
Power
mode
Used to
activate/deactivate
the module.
Passive
Readable /
Writeable
Readable
N/A
Message
format
The message format
determines the
structure and payload
of the telegram sent
from the module.
0x1E
(Standard)
Readable /
Writeable
Readable
Writeable
EcoMode
When activated, 11+1
years of battery-life is
guaranteed by
adapting the transmit
interval of the module
to current signal
conditions.
On
Readable /
Writeable
Readable
Writeable
Transmit
interval
Sets the number of
minutes between each
transmission from the
module.
60 min
Readable /
Writeable
Readable
Writeable
Date &
Time
Date and time set for
the meter.
N/A
Readable
Readable
N/A
Set Time
Relative
Adjusts the time of the
meter relative to the
current time.
N/A
N/A
N/A
Writeable
Set
absolute
time
Sets the time of the
meter. When
synchronizing the time
via the Elvaco OTC
App, the date, time
and UTC offset
settings of the phone
will be applied to the
meter.
N/A
Writeable
N/A
N/A
Set UTC
offset
Sets the UTC offset of
the meter.
N/A
Readable /
Writeable
Readable
Witeable
Configurati
on Lock
Locks the module to
prevent unauthorized
access.
Open
Readable /
Writeable
Readable
Writeable