Technical Data
B.2
B.2
System Conditions
Numbers in the following table do not include the heater.
Table B-2:
System Conditions
110-120V
220-240V
Without UPS
Idle Mode
Operation (maxi-
mum)
Idle Mode
Operation (maxi-
mum)
Rated current con-
sumption (depends
on system configu-
ration)
1.2 A
2.4 A
0.6 A
1.4 A
Active Power
160 W
370 W (without
heater) [1] [2]
130 W
330 W (without
heater) [1] [3]
With UPS
Rated current con-
sumption
2.3 A
3.5 A
1.2 A
2.0 A
Active Power
300 W
500 W
240 W
460 W
Protection Class
1
1
Type of system
connection (wall
outlet)
Country-specific safety plug
Country-specific safety plug
Fuse
30A automatic circuit breaker
16A automatic circuit breaker
Degree of protec-
tion according to
EN 60529:
IP X0
IP X0
[1] One heater would add 700W. Two heaters (upper chassis
and safe) would add 1400W.
[2] Air conditioner adds 690W.
[3] Air conditioner adds 670W.
Copyright © 2021, Diebold Nixdorf
01750337284 C
B-2