Calibration Services - New Units

N100 - NIST Traceable Calibration 1-Point:

 Includes documentation to one Dickson pre-selected point 

on new units only.

N300 - NIST Traceable Calibration 3-Point:

 Includes documentation of three Dickson pre-selected 

points (a high, medium, and low) on new units only. 

N400 - Deluxe A2LA Accredited NIST Traceable Calibration 3-Point:

 ISO Guide 25/A2LA 

Documentation of 3 pre-selected points of as found data before and after calibration for Dickson 
temperature and/or humidity instrumentation on new units only.

N995 - NIST User Selected Temperature Points:

 Documentation of one customer specified point. 

Should be selected in addition to one of the above calibration options. 

The Importance and Benefits of Regular Calibrations

 

Once you begin to use your precision Dickson instrumentation, regular calibrations are necessary to ensure 
accurate readings.

The following Calibration Services are available:

N150 - NIST Traceable Calibration 1-Point:

 Includes documentation to one Dickson pre-selected point 

after re-calibration.

N350 - NIST Traceable Calibration 3-Point:

 Includes documentation of three Dickson pre-selected 

points (a high, medium, and low) after re-calibration. 

N450 - Deluxe A2LA Accredited NIST Traceable Calibration 3-Point:

 ISO Guide 25/A2LA 

Documentation of 3 pre-selected points of as found data before and after calibration for Dickson 
temperature and/or humidity instrumentation. 

N995 - NIST User Selected Temperature Points:

 Documentation of one customer specified point. 

Should be selected in addition to one of the above calibration options. 

Why should I recalibrate my instrumentation?

 

 

Over time dirt, dust and normal handling can throw your precision instrumentation out of calibration. 
Regular calibrations ensure that you receive the most accurate readings possible. 

How often should I recalibrate my instrumentation?

  

Depending on the environment your instrument is used in and how often it is handled you will want to 
recalibrate your instrument every 6 to 12 months. Instruments in environments where there are extreme 
temperatures, wide temperature ranges, humidity or pressure variations, high condensation, dirt, dust and 
other debris will require calibration at least every 6 months. Instruments that are frequently moved or in 
locations with heavy machinery that cause vibrations should also be calibrated at least every 6 months. 

Why should I return my instrument to Dickson for calibration?

  

Dickson calibrates your instrument at the factory using proprietary production/calibration software that 
guarantees proper calibration.

Our Capabilities

 

Dickson is the first manufacturer of humidity and temperature instrumentation to   receive A2LA 
accreditation. We are also NIST Traceable; our procedures conform to MIS-STD-45662A, ANSI/NCSL 2540-
1-1994, ISO/IEC Guide 25 and ISO10012. We are experts in the manufacture and calibration of humidity and 
temperature instruments.  

  Fast Service:

 Our turnaround time is 3 days or less so you receive not only expert service but fast  

 

    service as well. 

  Easy:

 We make it easy for you! No phone calls for Return Authorization Numbers are required. We  

 

  remind you when your instrument is due for calibration. You simply send in the completed Calibration 

  Order Form with your unit for calibration with freight prepaid to Dickson. 

Pr

od

uc

 

Sp

ec

ifi

ca

tio

ns &

A

pp

lic

at

io

ns 

Q

uic

k S
ta

rt

/

O

pe

ra

tin

In

st

ru

ct

io

ns 

Ch

ar

ts &

A

cc

es

so

rie

s

C

ali

br

at

io

ns

Tr

ou

ble

sh

oo

tin

& W

ar

ra

nt

y

Sp

an

is

h

Fr

en

ch

G

er

m

an

Ita

lia

n

Continued on next page

Summary of Contents for TH6

Page 1: ...fications Applications Quick Start Operating Instructions Charts Accessories Calibrations Troubleshooting Warranty Spanish French German Italian DICKSON TH6 Temperature Chart Recorder Contents Product...

Page 2: ...ameter 6 Battery Life Avg 72 hours Backup Only Recording Times 24 Hour 7 Day Response Time 2 5 minutes Alarm TH623 25 Audio Visual on High Low Temp RH Limits Relay Type SPST 24VDC 0 5A NO NC Relay doe...

Page 3: ...just the chart time press and hold ADJUST UP and ADJUST DOWN buttons located on the back of the unit next to the dip switch see figure 3 The green LED will blink rapidly for about five seconds then th...

Page 4: ...larm min e pen alarm max In order to set pen alarm minimums and maximums pressing ADJUST UP will increase the alarm value and pressing ADJUST DOWN will decrease the alarm value There is acceleration i...

Page 5: ...or on position Slide toggle down for off position Dip Switch 1 7 8 are not active on this recorder Temperature Range The TH6 will record up to 4 temperature ranges depended on model Dip switch 3 4 all...

Page 6: ...e Adjust Up button the led will then blink amber at which point only the pen being adjusted will show on the display To raise the unit of measurement press the Adjust Down button To lower the unit of...

Page 7: ...dirt dust and normal handling can throw your precision instrumentation out of calibration Regular calibrations ensure that you receive the most accurate readings possible How often should I recalibrat...

Page 8: ...y instrument The model number serial number and a purchase order number will be requested before an RA number is issued Carefully repack the instrument label the outside of the box with the RA and ret...

Page 9: ...de la punta del estilete en el cuadrante b Esta caracter stica s lo debe utilizarse para ajustes finos Para ajustar el tiempo del gr fico pulse y mantenga apretados los botones ADJUST UP y ADJUST DOWN...

Page 10: ...UST UP para aumentar el valor de la alarma y ADJUST DOWN para disminuir su valor Se produce aceleraci n si se mantiene apretado el bot n ADJUST UP Pulse repetidamente el bot n PEN HOME para que se des...

Page 11: ...Italian 1 2 3 4 5 6 7 8 Conmutaci n deslizante hacia arriba para posici n de conexi n Conmutaci n deslizante hacia abajo para posici n de desconexi n Rangos de Temperatura El TH6 Puede registrar hasta...

Page 12: ...r b Cette fonction ne devrait tre utilis e que pour l affinage de l ajustage Pour ajuster l heure du graphe pressez et maintenez enfonc s les boutons ADJUST UP et ADJUST DOWN situ s l arri re de l uni...

Page 13: ...OWN pour la diminuer Il y aura une acc l ration si le bouton ADJUST UP est maintenu enfonc Une pression r p t e de PEN HOME fera d filer les cinq options jusqu ce que soit press le bouton d alarme our...

Page 14: ...ctions Charts Accessories Calibrations Troubleshooting Warranty Spanish French German Italian Port e de temp rature L appareil TH6 enregistrera jusqu cinq port es de temp rature selon le mod le Le com...

Page 15: ...e der W hlerscheibe b Dieses Feature sollte nur zur Feineinstellung verwendet werden Um die Diagrammzeit einzustellen passen Sie die Diagrammzeit an dr cken und halten Sie die neben dem Abblendschalte...

Page 16: ...den Stift wird durch Dr cken von ADJUST UP der Alarmwert erh ht und durch Dr cken von ADJUST DOWN der Alarmwert erniedrigt Durch Gedr ckthalten des ADJUST UP Buttons wird dieser Einstellvorgang besch...

Page 17: ...ts Accessories Calibrations Troubleshooting Warranty Spanish French German Italian Temperaturbereich Der TH6 zeichnet bis zu f nf Temperaturbereiche auf in Abh ngigkeit vom Modell Abblendschalter Nr 3...

Page 18: ...ul quadrante b Questa funzione deve essere usata solo per regolazioni di precisione Per regolare l ora del diagramma premere e tenere premuti i pulsanti ADJUST UP e ADJUST DOWN che si trovano a tergo...

Page 19: ...rme e premendo ADJUST DOWN si diminuisce il valore dell allarme Si accelera se il pulsante ADJUST UP tenuto premuto Premendo ripetutamente il pulsante PEN HOME si scorrono le 5 possibilit fino a quand...

Page 20: ...s Charts Accessories Calibrations Troubleshooting Warranty Spanish French German Italian Campo temperatura Il TH6 registrer fino a 4 campi di temperatura a seconda del modello Gli interruttori Dip 3 4...

Reviews: