OPERATOR’S MANUAL
PM300E and PM332E Planter Monitors
11001-1423-200710
OPERATE MODE / 31
2. At the Upper Parameter icon, press Enter to display the Upper
Parameter Setup screen.
3. Use the Down Arrow key to highlight the Graphic/Text icon.
4. Press Enter key to select the icon. Use the Up or Down Arrow key to
toggle to desired setting.
5. Press Enter to confirm selection.
CHANGING PLANTING PARAMETERS
Several planting parameter choices are available for viewing on the Main
Operate screen with a maximum of 4 viewable lines displayed. Available
planting parameter choices are listed below.
To Select a Planting Parameter:
1. At the Upper Parameter icon, press Enter to display the Upper
Parameter Setup screen.
2. With the Edit icon highlighted, press the Enter key again.
3. Use the Up or Down Arrow keys to select a position to change.
4. Use the Right or Left Arrow keys to scroll the listing of planting
parameters.
5. Press Enter to accept the selection.
AVAILABLE PLANTING PARAMETERS
AVERAGE POPULATION
Average Population
displays the average of the planter's rows that are
configured for population in thousands of seeds per hectare (s/ha) or
thousands of seeds per acre (s/ac). The population response rate and
population adjustment can be modified on the target setup screen. This
function can be labeled with a symbol or text, depending on the text/graphic
setting.
MINIMUM/AVERAGE/MAXIMUM POPULATION
Minimum/Average/Maximum Population
alternates the display of the
minimum row, planter average, and maximum row every two seconds.
When a minimum or maximum row is displayed, the corresponding symbol
is shown with the row number.
POPULATION ROW SCAN
Population Row Scan
displays the population of each of the planter’s
rows. The displayed row is incremented every two seconds. After the last
row is displayed, the scan will resequence beginning with the first active
row.
AVERAGE SPACING
Average Spacing
displays the average seed spacing (cm or inches) of the
planter's rows that are configured for population. This function can be
labeled with a symbol or text, depending on the text/graphic setting.
123.4
43.8
1 2 3 4
123.4
43.8
123.4
567.8
912.3
...
Display & Service icon
Upper Parameter icon
Edit icon
Summary of Contents for PM300E
Page 4: ...OPERATOR S MANUAL PM300E and PM332E Planter Monitors 11001 1423 200710 2 SAFETY NOTICES...
Page 8: ...OPERATOR S MANUAL PM300E and PM332E Planter Monitors 11001 1423 200710 6 INTRODUCTION...
Page 10: ...OPERATOR S MANUAL PM300E and PM332E Planter Monitors 11001 1423 200710 8 MAJOR FEATURES...
Page 14: ...OPERATOR S MANUAL PM300E and PM332E Planter Monitors 11001 1423 200710 12 INSTALLATION...
Page 30: ...OPERATOR S MANUAL PM300E and PM332E Planter Monitors 11001 1423 200710 28 AUXILIARY MODES...
Page 46: ...OPERATOR S MANUAL PM300E and PM332E Planter Monitors 11001 1423 200710 44 TROUBLESHOOTING...
Page 48: ...OPERATOR S MANUAL PM300E and PM332E Planter Monitors 11001 1423 200710 46 CONNECTOR PINOUTS...