Instalab 700 Quick Start Guide

11001-1608-201702 Rev B

 5

INSTALAB 700 QUICK START GUIDE

PASSWORD RESTRICTIONS

Setting an administrator user name and password to restrict modification of system settings to an administrator are optional. The 
unit is shipped with an Admin user name of “GUEST” and password setting of “GUEST”. The Admin user name screen is found in 
the Setup.
Keeping the Admin user name and password as “GUEST” retains the unit in open access mode allowing any user to enter System 
Settings and modify unit settings. Press the 

Enter

 button to proceed. 

IMPORTANT: 

To restrict access to System Setup that affects 

overall unit functionality, a new Admin User name and password must be created. Refer to the Operator’s manual (System Setup) 
for creating a name and password.

Figure 3
Password Screen (Open Access)

IMPORT PRODUCT

New products can be loaded to the IL700 using a USB memory device. Follow the onscreen instructions to begin file import.

1. Insert USB memory device into unit.
2. At the Main Menu, press the 

Setup

 button.

3. At the System Setup screen, press the 

Product

 button.

4. At the Products List screen, press the 

Import

 button.

5. Select the desired directory, if shown, displayed in the Directory Contents window. The number of directories and/or files on 

the USB displays on screen.

6. Press the 

Enter

 button to view calibration (.cal) files.

Figure 4
Import Product

7. The number of files stored on the USB device display in the Directory Contents window. Pressing “..\” displayed in the 

Directory Contents window returns to the previous level in the directory structure. 

8. Press the 

Enter

 button again to display the file name on the USB.

9. Select the checkbox(s) for the files to import.The box must be checked for the download to occur.

10. Press the 

Import

 button to begin import. 

11. Verify product(s) imported at the Product List screen.

Admin Username

INSTALAB 700

Admin Username

INSTALAB 700

GUEST

Enter User Name:

Enter Password:

GUEST

Please Log in

Select Directory

INSTALAB 700

Select Directory                                                     

INSTALAB 700

Directory Contents

1 Directories, 0 Files Exist. Push ENTER to
view.

\Hard Disk\ 

Products List                                                                   

INSTALAB 700

Products List                                                                   

INSTALAB 700

Copy

Barley

IL700.Barley.20091229.cal

Corn Meal

IL700.Corn_Meal.20080405.cal

DDGS

IL700.DDGS.20100528.cal

DDGS_1

IL700.DDGS.20100529.cal

HRW Wheat IL700.HRWW.20091124.cal

Delete

Edit

Import

Label

File

IL700.HRWW.2011050
IL700.SOYBEANS.20110505

CORN

IL700.CORN.20110505

HRWW
SOYBEANS

4

5

6

11

Samples\

System Setup                                            

INSTALAB 700

System Setup                                            

INSTALAB 700

Product

System

Database

Diagnostics

3

Summary of Contents for INSTALAB 700

Page 1: ...UTION without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in equipment damage DISCLAIMER DICKEY john reserves the right to make engineering refinements or procedural changes that may not be reflected in this manual Material included in this manual is for informational purposes and is subject to change without notice INTRODUCTION This quick st...

Page 2: ...proper operation of the unit The grounding pin on the power cord plug is connected to the Instalab enclosure If an adapter with a grounding wire is used verify the grounding wire is connected to a good earth ground Otherwise a shock hazard may be present Do not use a 3 pin to a 2 pin adapter UNIT OVERVIEW Figure 1 IL700 Appropriate space must be left around the input power connector to allow easy ...

Page 3: ... or the On Off button CLEAR Removes a test result and does not save the result to the database PRINT Prints test results to a connected printer INSTRUMENT INFORMATION Appears on the Main Menu screen providing details regarding unit service date serial number and software version Typically used for troubleshooting purposes BACK Returns to the previous screen LCD DISPLAY TOUCH SCREEN CALIBRATION Re ...

Page 4: ...point of 50 00 degrees C The bar turns green when the temperature is within 10 degrees C of the setpoint Upon power up of the unit the temperature will climb to 50 00 degrees C and likely overshoot Some oscillation will occur before stabilizing A temperature warning appears when the bar is red but analysis can still occur and is flagged with a symbol indicating the result is suspect IMPORTANT It i...

Page 5: ...ory if shown displayed in the Directory Contents window The number of directories and or files on the USB displays on screen 6 Press the Enter button to view calibration cal files Figure 4 Import Product 7 The number of files stored on the USB device display in the Directory Contents window Pressing displayed in the Directory Contents window returns to the previous level in the directory structure...

Page 6: ...screen appears only if a sample ID and or a customer ID is required 8 Press the Enter button to proceed When enabled Auto Sequencing will automatically enter the next sample ID number When enabled Last Used Customer ID will continue loading a Customer ID until the next power cycle occurs If neither are required this screen is skipped INSTALAB 700 INSTALAB 700 Label File HRWW_4 IL700 HRWW_4 2011090...

Page 7: ...calibration Alt MB Alternate moisture basis Temp Out of Limits A reading taken when the optics temperature is too high or too low INSTALAB 700 INSTALAB 700 OPEN DRAWER Product CORN File IL700 Corn 2101229 cal INSTALAB 700 INSTALAB 700 INSERT SAMPLE Ref Scanning INSTALAB 700 Ref Scanning INSTALAB 700 Please wait Product CORN File IL700 Corn 2101229 cal Screen does not appear if reference already re...

Page 8: ...try of a specified number of days to display or print starting with the most current date PRODUCT NAME Allows entry of a product name to perform a product search Exact product name must be entered to find results but is case insensitive CUSTOMER ID Allows entry of a specific customer ID to view or print Results View INSTALAB 700 Results View INSTALAB 700 06 Mar 09 02 04 PM 06 Mar 09 02 04 PM 06 Ma...

Reviews: