INSTALAB 700 QUICK START GUIDE

Instalab 700 Quick Start Guide

11001-1608-201702 Rev B

 1

Safety notices are one of the primary ways to call attention to potential hazards.

This Safety Alert Symbol identifies important safety messages in this manual. When you see this 
symbol, carefully read the message that follows. Be alert to the possibility of personal injury or death.

Use of the word WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or 
serious injury.

Use of the word CAUTION with the Safety Alert Symbol indicates a potentially hazardous situation which, if not 
avoided, may result in minor or moderate injury.

Use of the word CAUTION without the safety alert symbol indicates a potentially hazardous situation which, if not 
avoided, may result in equipment damage.

DISCLAIMER

DICKEY-john reserves the right to make engineering refinements or procedural changes that may not be reflected in this manual. 
Material included in this manual is for informational purposes and is subject to change without notice.

INTRODUCTION

This quick start guide provides the minimum requirements to begin using the Instalab 700 NIR Grain Analyzer and is organized 
according to typical sequential actions for installation, startup, analyzation, and results.
More detailed information is available in the Operator’s manual that addresses:

Installation

Calibrations

Sample preparation

Navigation

Password restrictions

System setup

Startup

Analyzing

Results

Database Storage and Record Deletion

Diagnostics

Troubleshooting

Maintenance

!

Summary of Contents for INSTALAB 700

Page 1: ...UTION without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in equipment damage DISCLAIMER DICKEY john reserves the right to make engineering refinements or procedural changes that may not be reflected in this manual Material included in this manual is for informational purposes and is subject to change without notice INTRODUCTION This quick st...

Page 2: ...proper operation of the unit The grounding pin on the power cord plug is connected to the Instalab enclosure If an adapter with a grounding wire is used verify the grounding wire is connected to a good earth ground Otherwise a shock hazard may be present Do not use a 3 pin to a 2 pin adapter UNIT OVERVIEW Figure 1 IL700 Appropriate space must be left around the input power connector to allow easy ...

Page 3: ... or the On Off button CLEAR Removes a test result and does not save the result to the database PRINT Prints test results to a connected printer INSTRUMENT INFORMATION Appears on the Main Menu screen providing details regarding unit service date serial number and software version Typically used for troubleshooting purposes BACK Returns to the previous screen LCD DISPLAY TOUCH SCREEN CALIBRATION Re ...

Page 4: ...point of 50 00 degrees C The bar turns green when the temperature is within 10 degrees C of the setpoint Upon power up of the unit the temperature will climb to 50 00 degrees C and likely overshoot Some oscillation will occur before stabilizing A temperature warning appears when the bar is red but analysis can still occur and is flagged with a symbol indicating the result is suspect IMPORTANT It i...

Page 5: ...ory if shown displayed in the Directory Contents window The number of directories and or files on the USB displays on screen 6 Press the Enter button to view calibration cal files Figure 4 Import Product 7 The number of files stored on the USB device display in the Directory Contents window Pressing displayed in the Directory Contents window returns to the previous level in the directory structure...

Page 6: ...screen appears only if a sample ID and or a customer ID is required 8 Press the Enter button to proceed When enabled Auto Sequencing will automatically enter the next sample ID number When enabled Last Used Customer ID will continue loading a Customer ID until the next power cycle occurs If neither are required this screen is skipped INSTALAB 700 INSTALAB 700 Label File HRWW_4 IL700 HRWW_4 2011090...

Page 7: ...calibration Alt MB Alternate moisture basis Temp Out of Limits A reading taken when the optics temperature is too high or too low INSTALAB 700 INSTALAB 700 OPEN DRAWER Product CORN File IL700 Corn 2101229 cal INSTALAB 700 INSTALAB 700 INSERT SAMPLE Ref Scanning INSTALAB 700 Ref Scanning INSTALAB 700 Please wait Product CORN File IL700 Corn 2101229 cal Screen does not appear if reference already re...

Page 8: ...try of a specified number of days to display or print starting with the most current date PRODUCT NAME Allows entry of a product name to perform a product search Exact product name must be entered to find results but is case insensitive CUSTOMER ID Allows entry of a specific customer ID to view or print Results View INSTALAB 700 Results View INSTALAB 700 06 Mar 09 02 04 PM 06 Mar 09 02 04 PM 06 Ma...

Reviews: